ZHOU Ning
Abstract:Focusing on the central position of AC power frequency converter in the development of the nationaleconomy,emphasizingd their critical impact on the safety and efficiency of industrial production. In view of the rapid development of power electronics technology,the field of AC power frequency converter has ...
更多
Number of views:3409 Amount of downloads:7821
-
YANG Xuan,LI Rui,CAO Xiaoqing,LI Lin,GUO Ran
Abstract:During the transition of a microgrid inverter from grid-connected mode to islanded mode and viceversa,pre-synchronization measures are necessary under the virtual synchronous generator (VSG) controlarchitecture to prevent voltage waveform distortion and current surges. A VSG-based parameter-optimized presyn...
更多
Number of views:3408 Amount of downloads:15121
-
SHI Liguo,LI Yanzhen,LI Yuanfu,GUAN Xuelin,XU Zhigen,ZHANG Mingyuan
Abstract:Three-level neutral-point-clamped(3L-NPC)interconnected converters have been widely used inthe AC-DC hybrid distribution grids due to their superiorities of large capacity and high power quality. However,their working conditions are always with high power,varying load,and limited heat dissipation,etc.,with ...
更多
Number of views:3398 Amount of downloads:10685
-
FENG Kan,ZHANG Lezhen,ZHOU Long,HOU Yanlun,NIU Wei,BAO Chengjia
Abstract:An improved virtual impedance strategy with adaptive reactive power equalisation and bus voltagecompensation functions was proposed to address the reactive power equalisation and bus voltage drop issues inparallel inverters in island microgrids. By introducing an enhanced power decoupling strategy based on ...
更多
Number of views:3382 Amount of downloads:16825
-
CUI Yulu,SHANG Xingming,QIAN Xin,TONG Xiaoqing,ZHANG Zhiguo
Abstract:In response to the susceptibility of wind storage DC building microgrid systems to externalinterference,the DC bus is prone to instability during multi-mode switching and high-power load switching,posing a serious threat to the safe and reliable operation of electrical equipment. A large-signal simplified m...
更多
Number of views:3358 Amount of downloads:12927
-
ZHENG Bining,YAN Dong,SONG Peng,ZHANG Zhen,YAN Yan
Abstract:The structure parameters of dual-stator permanent magnet synchronous motors(DSPMSM)wereoptimized with finite element methodTaguchi method at the rated point,maximum torque point,and maximum speed point,respectively,aiming at the problem of large torque ripple of DSPMSM. The influence onelectromagnetic torqu...
更多
Number of views:3347 Amount of downloads:11877
-
LIU Zhongmin,ZHAO Danyang
Abstract: Non-invasive load monitoring monitors the working status of each electric equipment by installingan intelligent meter at the main power interface,aiming to collect and analyze users' power consumptioninformation in real time. According to different characteristics of household user load change in power...
更多
Number of views:3344 Amount of downloads:9228
-
LU Shanshan,LI Li,LI Lin,SUN Haibo,WU Runze
Abstract:In recent years,the large-scale access of a large number of new power distribution services such asdistributed power generation,electric vehicles,and flexible load control has led to a sharp increase in the operating pressure of the power cloud master station. To this end,an adaptive resource allocation met...
更多
Number of views:3342 Amount of downloads:14391
-
WANG Yubo,AN Yang,QIU Shuming,GAO Zhuoxuan,SUN Furun
Abstract:Inverter products have been developing towards higher power density and more compact structure.To enhance the power density of inverter systems within a limited structural space,several prototypes need to bemade and a large number of experiments conducted during the research and development process. To shor...
更多
Number of views:3335 Amount of downloads:12308
-
LIU Kai,LI Gang,WANG Xin
Abstract: According to the 90 s regular breaking and 15 s emergency breaking requirement for 60 MW axialcompressor used in some large scientific facility,a control strategy of electric hybrid breaking in the convertor wasdesigned. The hybrid braking control strategy was analyzed and calculated,and the optimal brakin...
更多
Number of views:3330 Amount of downloads:16165
-
LI Xinhai,FAN Dehe,MENG Chenxu,ZENG Lingcheng,YUANTuolai
Abstract: Due to various environmental factors,the relay platen status recognition needs manual inspection fora long time,and the current popular platen image recognition program requires a huge background computingarchitecture,which can not immediately obtain the verification information in the operation site,and s...
更多
Number of views:3308 Amount of downloads:15028
-
ZHANG Jinbo,YAN Lei,SHI Jian,HUANG Xiaoyu,YANG Dishan,YAN Tongyu
Abstract: A large number of voltage fluctuations will occur in the grounding process of optical storage DCmicrogrid,which has a bad impact on the stability of microgrid power signal. Due to the poor voltage disturbancesignal capture ability of the present optical storage DC microgrid grounding anti-interference tech...
更多
Number of views:3306 Amount of downloads:6754
-
WANG Shixin,YU Bo,YUAN Yong,SI Guolei,DAI Jin,CAO Taiqiang
Abstract: Electric valve regulation requires fast response speed,high precision control,no overshoot andstrong anti-interference performance. An active disturbance rejection algorithm based on feedforward compensation was used to control the brushless DC motor(BLDC),and the position error was taken as the input of t...
更多
Number of views:3295 Amount of downloads:7995
-
HE Yongpeng,WANG Mingyue,WANG Yubo,WANG Chunhui,ZHAO Zesheng
Abstract:Based on the parallel structure of high-power converter system,a high real-time and highsynchronization optical-fiber communication scheme was proposed. The on-fly transmission ensures that thecommunication between the controllers has a low delay,and the clock synchronization algorithm compensates thetime-d...
更多
Number of views:3293 Amount of downloads:14784
-
MAO Fang,MIAO Xinzhao,LIANG Qianyuan,TANG Fangwen
Abstract:Compared to partial life cycle assessment,the full life cycle assessment is more complex anduncertain,with the difficulty of comprehensively considering carbon emissions and their multiple influencingfactors at each stage,resulting in fuzzy assessment boundaries and dynamic repetition of the process. To thi...
更多
Number of views:3286 Amount of downloads:12800