-
YUE Yuanyuan,ZHANG Chao,YUAN Xingzhong,ZHU Anming, HUANG Zongjun,JIANG Bo,ZHANG Yuhan
Abstract: The spatial load of multi-power distribution network is easy to overload,which leads to thereduction of distribution network planning stability. A dynamic planning and optimization method of multi-powerdistribution network considering the spatial load layout was proposed. According to the equivalent topolo...
更多
Number of views:4268 Amount of downloads:8907
-
LIU Ronghui,MA Tiantian ,SUN Gaiping
Abstract:The potential dispatchable resources of electric power,heat,cool and gas in the integrated energysystem(IES)are important contributors to reduce the operating cost of IES. In order to guarantee the customersatisfaction while reducing operating cost of IES,a IES day-ahead optimal dispatch model considering a...
更多
Number of views:4265 Amount of downloads:9370
-
HU Xiaoyu,ZHOU Yuanxiang,CHEN Jianning,ZHAO Yunzhou,LIU Jun
Abstract: As a new type of insulating oil in the power industry,natural gas insulating oil is excepted to solvethe bottleneck problem of high-quality transformer oil's insufficient supply in the future. However,its electricalparameters including partial discharge withstand strength and sweep frequency spectrum c...
更多
Number of views:4243 Amount of downloads:8482
-
NIU Shengsuo,CHENG Bo,LI Jinbo,LÜ Linfei,FU Xiulai
Abstract: Avoltage disturbance detection method based on mathematical morphological filtering and derivationdq transformation was proposed. Firstly,in order to reduce the interference of pulses,harmonics and other noises in the signals to be detected,a composite morphological filter was constructed based on adaptive...
更多
Number of views:4240 Amount of downloads:8566
-
SHEN Hangyu,FAN Xiaochao,SHI Ruijing,WANG Weiqing, WANG Haiyun,CHENG Zhijiang
Abstract: In order to solve the problem of heat dissipation in the process of producing hydrogen fromelectrolytic water and generating electricity from fuel cells,an independent photohydrogen fuel cell thermoelectriccombined supply system was designed according to the principle of water cooling heat dissipation betw...
更多
Number of views:4237 Amount of downloads:9902
-
LU Heng,LIU Haitao,XIA Tao,ZHANG Chengyu,HUANG Cheng
Abstract:Accurate line parameters are of great significance to the operation and control of the distributionnetwork. However,the line parameters of distribution network are affected by environment,working condition and temperature,etc. At the same time,due to the increasing complexity,randomness and volatility of di...
更多
Number of views:4235 Amount of downloads:9680
-
DAI Feng,CHEN Xuan,WANG Lixian,MA Hongzhong
Abstract: Partial discharge fault diagnosis and location of gas insulated metal enclosed transmission line(GIL)is of great significance for its internal insulation protection. Because GIL is fully enclosed structure,theexisting external detection method is not sensitive to the internal defect detection,so it is unab...
更多
Number of views:4225 Amount of downloads:9181
-
LIU Zhen,ZHU Zimin,WANG Xiaoyun,NAN Dongliang,DUAN Yu,WU Xiaofang
Abstract:As the penetration of renewable energy in power systems increases,converter-based devices aregradually becoming dominant in the grid. In terms of system frequency stability support,grid-forming converters,which can provide both active inertia support and fast frequency response services,hold great potential...
更多
Number of views:4218 Amount of downloads:21597
-
YE Jianmin,WANG Ruoyu,LUO Hongmei,XIE Yan
Abstract: The receiving end hybrid line commutated concerter based voltage source converter(LCC-VSC)notonly has the advantages of LCC and VSC,but also adopts the structure of high-voltage valve group LCC and lowvoltage valve group three-end parallel VSC in series at the receiving end. Therefore,the receiving end hyb...
更多
Number of views:4211 Amount of downloads:10859
-
CHEN Linghan,LU Jia
Abstract: As the hub node in the energy internet,the transformer can adjust and control power quality,thenormal and stable operation of transformer is of great significance to the safe and stable operation of the energyinternet. In order to accomplish this objective,status assessment of energy internet transformer b...
更多
Number of views:4208 Amount of downloads:8900
-
HE Hengjing,ZHOU Shangli,ZHANG Bensong,XIE Wenwang,LIAN Xinkai,XU Haotian
Abstract: In order to apply the non-instrusive load montiring technology into the new generation of smartmeter,a kind of method based on the BP neural networks enhancement algorithm of clustering for loadidentification was presented. In this method,each feature was relatived to the corresponding cluster based on the...
更多
Number of views:4206 Amount of downloads:9451
-
ZHANG Feifei,ZHANG Jun,WU Long,WU Xiaohui,XUE Zhanbo
Abstract: In order to solve the problems of false alarm rate and missing alarm rate in the traditional faultdetection method of substation primary equipment,a fault detection method of substation primary equipment based on deep convolution neural network was proposed. The substation primary equipment image and scene...
更多
Number of views:4201 Amount of downloads:7221
-
LIU Tong,YIN Zhonggang,BAI Cong,YUAN Dongsheng
Abstract: In order to improve the position sensorless control performance of permanent magnet synchronouslinear motor(PMSLM),a position sensorless control method based on disturbance compensated flux observer(DCFO)was studied. This method treats the notch filter as a disturbance observer and combines it with a feedb...
更多
Number of views:4196 Amount of downloads:16574
-
LI Lingxin,JIAO Yuping,SUN Jiacheng,DENG Fujin,ZHANG Qi,REN Biying
Abstract: High voltage converter is often used in high voltage direct current(HVDC)transmission system tocontrol power supply nearby at high potential. However,the high bus voltage and its wide range fluctuation in themodule pose a challenge to the high reliability design of power supply. To solve this problem,a hig...
更多
Number of views:4191 Amount of downloads:12694
-
CHEN Guoping,WANG Juan,LIANG Zhen,ZHANG Zhiyu,BAI Haibin,SUN Qianhao
Abstract: The full fault-blocking converter(FFBC)-based DC power distribution network is an importantdirection of the power system with source-load-storage interaction. Since there is no DC breaker in FFBC-DCpower distribution network,the start-up,mode switching and fault handling control strategies of FFBC-DC power...
更多
Number of views:4163 Amount of downloads:8910