WANG Yihan,FENG Chuanxin,JIN Tao
Abstract:To solve the problem of neutral point voltage imbalance when the three-level neutral point clamped(NPC)inverter works,an improved neutral balance model predictive control(INB-MPC)algorithm was proposed.The proposed method used a two-stage voltage vector selection method with no weighting factors,deleted the...
更多
Number of views:90 Amount of downloads:105
-
QU Chenming,GUO Kunli,BAI Yang,LI Hang,ZHU Tinghua,MA Peng
Abstract:Considering the influence of grid voltage background harmonics in weak current networks,reverseharmonic peaks appear in the grid-connected current under weighted average current control(WACC),making itimpossible for the system to achieve zero pole cancellation and thus affecting the stability of the grid-co...
更多
Number of views:98 Amount of downloads:98
-
CAO Dayou,LÜ Junmu,BAI Yansong,LI Guorong,ZHOU Yan
Abstract:In order to reduce the carbon emissions of large ships,photovoltaic(PV)power generationtechnology began to be applied to ship power systems. However,due to the limited capacity,low inertia and largeload difference of the ship power system,the traditional virtual synchronous generator(VSG)control strategy ca...
更多
Number of views:60 Amount of downloads:47
-
ZOU Yingdong,WANG Fengjun,ZHOU Yu
Abstract:This research focused on the separation and calculation of electromagnetic losses in semi-directdrived permanent magnet wind generators(SDDPMWG). Firstly,analytical method for calculating core loss ofmotor considering harmonic current was derived based on the Bertotti method. The eddy current loss of perman...
更多
Number of views:219 Amount of downloads:265
-
SUN Chuanjie,TIAN Kai,XU Wenyuan,LU Beibei,LI Nan
Abstract:A brake unit based on IGCT was designed for different applications of frequency converter inindustrial scenes,especially the medium voltage frequency conversion system without feedback function. IGCTwas used as the main power device,and the parameters and characteristics of IGCT was analyzed. According to t...
更多
Number of views:215 Amount of downloads:242
-
GU Laiqiang
Abstract:The traditional three-phase pulse width modulation(PWM)rectifier requires six power switches.Due to the shoot-through problem between two switches on the same bridge arm,the control difficulty is increasedand overall system design becomes more complicated. A half-controlled three-phase PWM rectifier topolog...
更多
Number of views:219 Amount of downloads:272
-
ZHAO Yifu,ZHANG Guangbin
Abstract:In response to the existing problems of traditional diode based clamp type wind turbine inverters,ahybrid clamp type structure was introduced. Based on the analysis of its working principle,a method for switchingthe switch state and a vector optimization selection method that can avoid modulation waveform b...
更多
Number of views:284 Amount of downloads:294
-
LI Haoyuan,CHEN Guowei,LI Guanjun,WEI Lingfeng,LIN Da,WANG Xiangjin
Abstract:With the emergence of a large number of distributed power generations,various unbalanced andnonlinear loads are connected to the power grid,resulting in the distortion of the grid current,which brings adverse effects to both the power grid and electrical equipment. A multifunctional energy storage converter...
更多
Number of views:281 Amount of downloads:353
-
YANG Zhaohui,WEI Huadong,HE Liuqing,ZHANG Hao,PENG Guoping,SHI Ben
Abstract:Aiming at the problem of large switching loss of modular multilevel converter(MMC),startingfrom the switching frequency optimization strategy,the existing switching frequency optimization strategy wasimproved,and the accurate analytical formula of sub-module capacitor voltage based on the real-time value of...
更多
Number of views:245 Amount of downloads:323
-
DING Chaohui,YAO Fei,JANG Jun,GAO Ang,SHAO Gao
Abstract:The traditional predictive current control for three-phase LCL grid connected inverters has theproblems of large steady-state ripple and unstable switching frequency,which is not conducive to the quality of grid connected current and the design of filters. Therefore,an improved three vector fixed frequency ...
更多
Number of views:250 Amount of downloads:355
-
SI Dajun,WANG Jie,SHU Banggui,ZHANG Guangbin,SHU Hongchun
Abstract:The load of a submerged arc furnace has many advantages,such as large single-unit regulationcapacity,good communication conditions,easy control,and low economic retrofitting,making it an importantflexible regulation resource for the power grid. However,there is currently a lack of effective digital simulati...
更多
Number of views:244 Amount of downloads:322
-
CHEN Biao,HAN Zhongxiu,MA Liqiang,ZHANG Renhe
Abstract:The back-to-back active neutral-point-clamped(ANPC)converter,as the core component of theunified power flow controller of the distribution network,is widely used for the flexible closed-loop operation.However,the ANPC converter has more switching devices and commutation paths,which significantly increasesth...
更多
Number of views:260 Amount of downloads:319
-
XIE Jijin,HUANG Wendong,SHEN Kang,LIU Bin,MENG Ningjia,ZHANG Yuanyuan
Abstract:In order to improve the compensation effect of LCL-type shunt active power filter,a frequencyadaptive decimal delay repetitive control based on IIR filter was proposed. The resonance suppression loop of LCLwas designed through root locus and the design result was used as a new control object for repetitive ...
更多
Number of views:373 Amount of downloads:425
-
LI Jiayu,HAN Yuan,WANG Jianjun,PAN Yue
Abstract:Modular multilevel matrix converter(M3C)is a multilevel topology that can directly realize ACACconversion,which has good application prospects in high-voltage transmission systems and DC distributionsystems,but the existence of bridge-arm circulating channels inside the M3C leads to a very complex controlst...
更多
Number of views:409 Amount of downloads:342
-
SUN Yueyue,LI Mengda,PEI Guangyao,ZHU Hanghang,NING Han
Abstract:Since the compressed air energy storage system grid-connected inverter voltage is always influencedby voltage fluctuations of the power grid with little problem,for the sake of ameliorating the dynamic and stableperformance of the DC bus voltage of the inverter on the side of the grid and the actual output ...
更多
Number of views:309 Amount of downloads:387