ZHANG Chunxiang,LI Xin,SUN Ning
Abstract:DC high current comprehensive characteristic test device is used to detect the released characteristicsof DC low-voltage electrical overcurrent protection electrical device,which is used in low-voltage electricalindustry for DC products for long time delay,short time delay,instantaneous tripping test and sh...
更多
Number of views:23 Amount of downloads:16
-
DENG Yaping,JIA Hao,ZHANG Xiaohui,TONG Xiangqian,WANG Lu
Abstract:The accurate recognition of power quality disturbance(PQD)is one of the main problems to besolved after PQD occurrence,which is of great importance for responsibility dividing and power market reformprocess accelerating. Massive quantities of power quality monitoring data prepare the ground for the recognit...
更多
Number of views:67 Amount of downloads:54
-
HUANG Guanglei,TIAN Qidong,LIN Zhixian,ZHENG Weinan,XU Te,LI Bingran
Abstract:Due to the extensive addition of new energy systems,the number and types of power qualitydisturbances in the system are also increased accordingly. However,the traditional power quality disturbance(PQD)classification method has the problem of low accuracy and efficiency,and it is difficult to adapt to theex...
更多
Number of views:64 Amount of downloads:53
-
KE Ting,TIAN Songlin,ZHOU Hai
Abstract:In order to solve the problem of low accuracy of small substation fault diagnosis,a small substationfault diagnosis model based on cooperative game and cloud model was proposed. By analyzing the characteristicsand causes of faults,the diagnosis index system was established. Entropy method and expert weighti...
更多
Number of views:94 Amount of downloads:116
-
HUANG Licai,YANG Xu,ZHANG Jing,LUO Chuanxian,CHEN Jia,ZHANG Guozhi
Abstract:In view of the frequent occurrence of omissions and false alarms of partial discharge insulationdefects in on-site gas insulated switchgear(GIS),the partial discharge multi-source detection test platform was built by using true GIS to carry out the intermittent discharge test of metal contamination defect o...
更多
Number of views:97 Amount of downloads:88
-
GUO Jiahao,YANG Xiong,FANG Xin,LI Guanfei
Abstract: With the rapid development of primary and secondary fusion equipment,the detection efficiency ofthe traditional primary and secondary equipment testing method is very low,and it is no longer suitable for the new fusion switch equipment testing. In view of this,an integrated testing scheme for primary and s...
更多
Number of views:142 Amount of downloads:186
-
LÜ Jin,XU Li,SUI Dawei,GAO Qixin,XU Deshu
Abstract: With the rapid development of China's industrial economy,the demand for strip materials isincreasing,and the construction of strip production lines both domestically and internationally is growing year byyear. However,the complexity of large-scale rolling mill systems and the harsh working environment ...
更多
Number of views:155 Amount of downloads:197
-
ZHENG Junfeng,HUANG Jiyuan,CHEN Yuanyang,HU Xiangwei
Abstract: Aiming at the frequent voltage sag problem in power quality problems,a multifunctional voltage sagtreatment equipment was developed for user-side voltage sag treatment. Based on the modeling analysis of thesystem,the control algorithm of the system under grid-connected and off-grid compensation states and ...
更多
Number of views:188 Amount of downloads:204
-
YIN Qiyun,YANG Chen,LU Hongjian,ZHAO Xinyang,AN Yanjie,CHEN Haoyang
Abstract: Aiming at clarifying the interference effect of 5G electromagnetic radiation on relay protection andcommunication control equipment in converter station,a microstrip antenna simulation model with a centerfrequency of 3.5 GHz was established. Firstly,the propagation and attenuation law of electromagnetic ra...
更多
Number of views:191 Amount of downloads:209
-
YANG Xiaochu,WANG Guanwen,LUO Guogan,XU Shipeng,ZHANG Dingwang
Abstract: The composition of the double-fed induction generator(DFIG)is complex,and its operation andmaintenance are difficult. Due to the relatively complex electromagnetic transient characteristics of the fault,theextraction quality directly affects the reliability of the fault detection results of the DFIG. Aimin...
更多
Number of views:234 Amount of downloads:309
-
LIAO Zhiwei,ZHUANG Jing,WANG Bowen,ZHENG Guangyu,XIE Xunkai
Abstract: Aiming at the problems that high voltage direct current(HVDC)transmission line protection andfault location are vulnerable to lightning interference,and the traditional lightning interference identificationmethods of transmission line based on time-domain and frequency-domain features exist the problems of...
更多
Number of views:206 Amount of downloads:246
-
HUANG Feng,CUI Zhimei,HUANG Zhidu,JIANG Shengchao,FENG Bo
Abstract: In order to evaluate the safety status of transmission lines scientifically and objectively,a safetyanalysis model of transmission lines based on support vector machine-back propagation(SVM-BP)hybrid networkwas proposed. Firstly,the weather data,transmission line standard documents and defect data were pro...
更多
Number of views:269 Amount of downloads:321
-
WU Ning,CAI Jie,LIANG Gonghao
Abstract: As an important part of smart grid monitoring system,the security of power wide area measurementsystem is very important. Therefore,in order to ensure the integrity and confidentiality of communication data inpower wide area measurement system and the communication security between terminal devices in the ...
更多
Number of views:287 Amount of downloads:326
-
PENGTao
Abstract: The local leakage signal of high-voltage insulation equipment is weak and its characteristics are notobvious,which can only explain whether there is discharge. There is a phenomenon of missing judgment andmisjudgment in the actual positioning process,which is difficult to accurately locate the high-voltage...
更多
Number of views:290 Amount of downloads:280
-
TONG Xin,SONG Guobing,ZHANG Zhihua,WANG Junfeng,LEI Zhirong
Abstract: Due to the change of the ground parameters of the distribution network after the single-phasegrounding fault,the traditional active arc suppression method based on the ground parameters in the normaloperation state has a deviation between the compensation current reference value and the actual value. Incons...
更多
Number of views:317 Amount of downloads:340