CHEN Chen,DONG Pingxian,SONG Xiaofan,GUO Fang,QI Huanruo,DU Xiaotong
Abstract:After the distributed wind farm stations are integrated into the distribution network,due to thecharacteristics of wind farm short-circuit current amplitude control and frequency offset,the traditional three-stagecurrent protection of distribution network is difficult to accurately identify the fault on the...
更多
Number of views:529 Amount of downloads:426
-
CHEN Zheng,WU Yangjin,HUANG Dingjie,WANG Chaojun,FU Xinhui
Abstract:Under the background of limited resources and time,equipment maintenance is considered as aneffective way to maintain the stable operation of the system. In order to allocate maintenance resources efficiently,the most critical equipment in the system should be identified first namely those that will cause s...
更多
Number of views:770 Amount of downloads:645
-
JING Weiwei,FU Hui,ZHENG Xian,LI Shuangwei,SHI Mingming,ZENG jiang
Abstract:With the accelerated construction of new power system,the harmonic characteristics of power gridare becoming more and more complex. It is of great significance to study the effective statistical management ofharmonic data for evaluating the power quality of power grid. A statistical method of harmonic evalu...
更多
Number of views:839 Amount of downloads:627
-
LI Nengjun,YANG Haicheng,XU Xianke,LI Shushan,GAO Yuling
Abstract:The state of the DC system of substation is directly related to the normal operation of the substation.A new method for ground fault detection in substation DC systems,which is a combination of double-tree complexwavelet transform and singular value decomposition,was proposed to achieve fast and accurate lo...
更多
Number of views:792 Amount of downloads:632
-
LÜ Zhengyu
Abstract:The power transmission and transformation system is an important link of power transmission. Inorder to reduce the cost of operation and maintenance and improve the recognition effect,an application method of automatic identification and control of transmission and transformation vulnerable lines was propos...
更多
Number of views:798 Amount of downloads:422
-
ZHANG Chunxiang,LI Xin,SUN Ning
Abstract:DC high current comprehensive characteristic test device is used to detect the released characteristicsof DC low-voltage electrical overcurrent protection electrical device,which is used in low-voltage electricalindustry for DC products for long time delay,short time delay,instantaneous tripping test and sh...
更多
Number of views:772 Amount of downloads:460
-
DENG Yaping,JIA Hao,ZHANG Xiaohui,TONG Xiangqian,WANG Lu
Abstract:The accurate recognition of power quality disturbance(PQD)is one of the main problems to besolved after PQD occurrence,which is of great importance for responsibility dividing and power market reformprocess accelerating. Massive quantities of power quality monitoring data prepare the ground for the recognit...
更多
Number of views:900 Amount of downloads:487
-
HUANG Guanglei,TIAN Qidong,LIN Zhixian,ZHENG Weinan,XU Te,LI Bingran
Abstract:Due to the extensive addition of new energy systems,the number and types of power qualitydisturbances in the system are also increased accordingly. However,the traditional power quality disturbance(PQD)classification method has the problem of low accuracy and efficiency,and it is difficult to adapt to theex...
更多
Number of views:837 Amount of downloads:525
-
KE Ting,TIAN Songlin,ZHOU Hai
Abstract:In order to solve the problem of low accuracy of small substation fault diagnosis,a small substationfault diagnosis model based on cooperative game and cloud model was proposed. By analyzing the characteristicsand causes of faults,the diagnosis index system was established. Entropy method and expert weighti...
更多
Number of views:679 Amount of downloads:834
-
HUANG Licai,YANG Xu,ZHANG Jing,LUO Chuanxian,CHEN Jia,ZHANG Guozhi
Abstract:In view of the frequent occurrence of omissions and false alarms of partial discharge insulationdefects in on-site gas insulated switchgear(GIS),the partial discharge multi-source detection test platform was built by using true GIS to carry out the intermittent discharge test of metal contamination defect o...
更多
Number of views:663 Amount of downloads:572
-
GUO Jiahao,YANG Xiong,FANG Xin,LI Guanfei
Abstract: With the rapid development of primary and secondary fusion equipment,the detection efficiency ofthe traditional primary and secondary equipment testing method is very low,and it is no longer suitable for the new fusion switch equipment testing. In view of this,an integrated testing scheme for primary and s...
更多
Number of views:716 Amount of downloads:859
-
LÜ Jin,XU Li,SUI Dawei,GAO Qixin,XU Deshu
Abstract: With the rapid development of China's industrial economy,the demand for strip materials isincreasing,and the construction of strip production lines both domestically and internationally is growing year byyear. However,the complexity of large-scale rolling mill systems and the harsh working environment ...
更多
Number of views:811 Amount of downloads:787
-
ZHENG Junfeng,HUANG Jiyuan,CHEN Yuanyang,HU Xiangwei
Abstract: Aiming at the frequent voltage sag problem in power quality problems,a multifunctional voltage sagtreatment equipment was developed for user-side voltage sag treatment. Based on the modeling analysis of thesystem,the control algorithm of the system under grid-connected and off-grid compensation states and ...
更多
Number of views:740 Amount of downloads:787
-
YIN Qiyun,YANG Chen,LU Hongjian,ZHAO Xinyang,AN Yanjie,CHEN Haoyang
Abstract: Aiming at clarifying the interference effect of 5G electromagnetic radiation on relay protection andcommunication control equipment in converter station,a microstrip antenna simulation model with a centerfrequency of 3.5 GHz was established. Firstly,the propagation and attenuation law of electromagnetic ra...
更多
Number of views:800 Amount of downloads:700
-
YANG Xiaochu,WANG Guanwen,LUO Guogan,XU Shipeng,ZHANG Dingwang
Abstract: The composition of the double-fed induction generator(DFIG)is complex,and its operation andmaintenance are difficult. Due to the relatively complex electromagnetic transient characteristics of the fault,theextraction quality directly affects the reliability of the fault detection results of the DFIG. Aimin...
更多
Number of views:934 Amount of downloads:767