ZHANG Jie,CHEN Qiang,LUO Yuanfeng,QIN Jiming,WEI Juren,WU Beixing
Abstract:Power cable is an important carrier of power transmission. To solve the problems of low accuracyand large computation in voicing diagnosis with traditional convolutional neural network model,a novel cable faultdiagnosis method based on multiple voicing features and lightweight convolutional neural network w...
更多
Number of views:73 Amount of downloads:53
-
DANG Yihan,XU Chuanfang,WANG Shaozu
Abstract:Usually,the DC side of the traction rectifier requires a series LC resonant circuit to filter out thepulsating component of 2 times the grid frequency. When the resonant inductor on the DC side had a short-circuitfault,the pulsating component would be transferred to the motor side,the problems such as torque...
更多
Number of views:67 Amount of downloads:100
-
PEI Zhiqiang
Abstract:Aiming at the traditional mine hoist rocker arm bearing fault diagnosis technology which usuallyonly utilizes a certain specific geometric structure of the vibration dataset and fails to obtain the optimal similaritygraph structure,an intelligent diagnosis method for bearing faults based on adaptive graph e...
更多
Number of views:62 Amount of downloads:56
-
SHEN Zhangliang,CHEN Yini,LI Haomin,LIU Zihao,MA Hongzhong,GE Xuanhao
Abstract:A fault diagnosis model for isolation switches based on Markov transition field(MTF),catch fishoptimization algorithm(CFOA)improved pyramid vision transformer(PVT)was proposed to address theproblems of complex fault situations,strong noise in signal extraction,and insufficient feature extraction. Firstly,th...
更多
Number of views:185 Amount of downloads:136
-
CHI Yuhang,ZHAO Lu,GE Qiongxuan,LIU Xue,CHENG Shi
Abstract:Taking the switch tube open-circuit fault of dual bridge series resonant DC-DC converter(DBSRC)as the research object. Firstly,the basic working principle of DBSRC was summarized,and the open circuit faultcharacteristics of DBSRC converter were introduced. On this basis,the fault characteristics that can be...
更多
Number of views:193 Amount of downloads:115
-
QIAO Chunlin,JIN Chuxiong,CHEN Dong,LIU Jianming
Abstract:In response to the potential local electric field distortion and insulation weaknesses that may occurunder high-voltage operating conditions in 35 kV European cable connectors,a 35 kV European cable connectorsstructural design method based on adaptive geometric optimization was proposed. The method integrat...
更多
Number of views:181 Amount of downloads:134
-
JI Liang,XU Jun,GUAN Ya,CUI Jingxia,HE Jie,PAN Yihang
Abstract:The three-core underground cable in the distribution network works in a harsh environment. Due tothe influence of aging,external force,high temperature and humidity,the insulation of long-term live operation iseasily damaged and causes faults. Aiming at the single-phase grounding fault of cable in distribut...
更多
Number of views:339 Amount of downloads:288
-
PANG Bo,MENG Jing,ZHANG Yang,TA Na,WANG Haibo,DU Jing
Abstract:The accurate identification of hidden danger for power utilization in low-voltage substations plays animportant role in improving the quality of power supply and reducing the risk of accidents.To improve the accuracyof identifying hidden danger in low-voltage substations,a low-voltage user hidden danger for...
更多
Number of views:457 Amount of downloads:255
-
ZHANG Chunli,LIU Hongwen,FANG Pengxing,CHAI Chenchao,ZHANG Wenqiong
Abstract:Incidents such as the burning of electromagnetic voltage transformers(PT),damage to primaryharmonic suppressors,and fuse tripping occur frequently in low and medium voltage distribution systems due toferroresonance,severely affecting the safe and stable operation of the system. Therefore,through theoretical...
更多
Number of views:335 Amount of downloads:275
-
XIONG Wei,CHEN Long,LÜ Shunli,GUO Zhenyu,LU Xin
Abstract:To address the complexities of transformer condition assessment indicators and the overreliance onexpert judgment in the evaluation process,a novel method for fuzzy comprehensive assessment of transformercondition was introduced,which is based on gaming theory and an improved version of the D-S evidence the...
更多
Number of views:454 Amount of downloads:297
-
YAO Ying,GU Bing,FANG Zhengnan
Abstract:With the wide application of solar photovoltaic panels,the detection of hidden dangers and faults ofphotovoltaic panels has become more and more important. In order to improve the inspection efficiency ofphotovoltaic panels and the accuracy of defect detection,a target detection algorithm based on attention...
更多
Number of views:396 Amount of downloads:277
-
GE Yaming,ZHOU Chenbin,MENG Yihua,SHEN Jiaoxiao,CAO Haiou,REN Xuchao
Abstract:With the accelerated construction of new power systems,the scale and complexity of transmissionsystems are constantly increasing. Therefore,it is urgent to study transmission line fault diagnosis algorithms thatutilize multi-source data as driving sources and meet requirements for accuracy and low time cons...
更多
Number of views:554 Amount of downloads:460
-
YAN Kun,GAN Jingfu,LIU Hongshun,SUI Yizhen,HE Pengkang
Abstract:A fusion prediction method was proposed to predict and correct the calculation deviation of the toptransformer oil temperature model in IEEE guideline,so as to realize the more precise prediction of the transformertop oil temperature(TOT). Firstly,the characteristics of the transformer TOT model and the ext...
更多
Number of views:556 Amount of downloads:359
-
GENG Likai,HOU Juan,ZHANG Chunxiang,HU Wenying,LI Wenhua,LI Cuijuan
Abstract:Thermal and magnetic protection circuit breakers provided short circuit protection by instantaneoustripping devices. In the magnetic field formed by the coil with current,the moving armature and stationary coreovercomed the spring force and engage under the influence of electromagnetic force,thereby pushing...
更多
Number of views:484 Amount of downloads:290
-
DI Ya,ZHANG Jinhua,QIAN Yang
Abstract:In DC power grid,when serious metallic short circuit fault occurs in the DC side line of voltagesource converter(VSC),the fault current has the characteristics of a fast rising speed and a large peak. The DCcircuit breaker is used to isolate the fault,which greatly increases the requirements for the quick a...
更多
Number of views:426 Amount of downloads:323