Reliability and diagnosis
Current location:Home >Reliability and diagnosis
-
ZHANG Jinbo,YAN Lei,SHI Jian,HUANG Xiaoyu,YANG Dishan,YAN Tongyu
Abstract: A large number of voltage fluctuations will occur in the grounding process of optical storage DCmicrogrid,which has a bad impact on the stability of microgrid power signal. Due to the poor voltage disturbancesignal capture ability of the present optical storage DC microgrid grounding anti-interference tech...
更多
Number of views:2045 Amount of downloads:1171
-
SHI Shaoqing,ZHANG Leping,ZHANG Bensong,WU Haowen,LIAN Xinkai,DU Shushuai
Abstract: In order to apply the smart meters with load identification technology into real application,a nonintrusive load identification method using Mean-shift clustering algorithm with siamese network framework wasproposed. In this method,the load event was carried out for extracting the features,including active...
更多
Number of views:2200 Amount of downloads:1958
-
DING Zancheng,WANG Dajun,LI Wanxiang
Abstract: In view of the problem that the dangerous points in transmission lines affect the stability of powersystem,the technology of identifying and controlling the transmission line dangerous points based on multidimensional perception was studied,which can control the transmission line risk in time,reduce noise ...
更多
Number of views:2358 Amount of downloads:1405
-
CAOWei,GUI Shicheng,HUANG Ruanming,HE Bilun,QIN Huancheng
Abstract: With the expansion of the interconnection scale of the power system,the impedance ratio of thepower grid increased gradually,thereby the breaking capacity of the circuit breaker was affected by the increasingattenuation time constant of the DC component of the short-circuit current .At present,the periodic...
更多
Number of views:2360 Amount of downloads:1458
-
ZHANG Feifei,ZHANG Jun,WU Long,WU Xiaohui,XUE Zhanbo
Abstract: In order to solve the problems of false alarm rate and missing alarm rate in the traditional faultdetection method of substation primary equipment,a fault detection method of substation primary equipment based on deep convolution neural network was proposed. The substation primary equipment image and scene...
更多
Number of views:2259 Amount of downloads:1292
-
HU Xiaoyu,ZHOU Yuanxiang,CHEN Jianning,ZHAO Yunzhou,LIU Jun
Abstract: As a new type of insulating oil in the power industry,natural gas insulating oil is excepted to solvethe bottleneck problem of high-quality transformer oil's insufficient supply in the future. However,its electricalparameters including partial discharge withstand strength and sweep frequency spectrum c...
更多
Number of views:2218 Amount of downloads:1312
-
HE Hengjing,ZHOU Shangli,ZHANG Bensong,XIE Wenwang,LIAN Xinkai,XU Haotian
Abstract: In order to apply the non-instrusive load montiring technology into the new generation of smartmeter,a kind of method based on the BP neural networks enhancement algorithm of clustering for loadidentification was presented. In this method,each feature was relatived to the corresponding cluster based on the...
更多
Number of views:2414 Amount of downloads:1365
-
DAI Feng,CHEN Xuan,WANG Lixian,MA Hongzhong
Abstract: Partial discharge fault diagnosis and location of gas insulated metal enclosed transmission line(GIL)is of great significance for its internal insulation protection. Because GIL is fully enclosed structure,theexisting external detection method is not sensitive to the internal defect detection,so it is unab...
更多
Number of views:2393 Amount of downloads:1415
-
ZHUANG Gewei,GU Zhen ,FENG Xiuqing ,DUANYan
Abstract: Automatic verification system of smart meter may be abnormal in the long-term operation process,but the regular manual detection method can not timely learn the risk information,shortening the period of manual inspection will reduce the work efficiency of automatic verification. In most cases,the sample da...
更多
Number of views:2625 Amount of downloads:1261
-
LU Wu,ZHENG Renjie,ZHAO Wenbin,TANG Jiayuan
Abstract: Efficient and accurate short-term load forecasting is essential to the safe and stable operation of thepower system. A combined prediction model based on empirical mode decomposition(EMD)and gated recurrentunit(GRU)was proposed. First,the date factors ,meteorological factors and historical load factor were...
更多
Number of views:2621 Amount of downloads:1518
-
ZHANG Yi,CHANG Pengfei
Abstract: With the increasing penetration of large-scale wind and PV power within the power system,theywill inevitably participate in the load frequency contro(l LFC). Since the power output of wind and PV is unstable,which would affect the power balance of grid,thus cause unstable frequency. A LFC method based on d...
更多
Number of views:2679 Amount of downloads:1256
-
CHEN Linghan,LU Jia
Abstract: As the hub node in the energy internet,the transformer can adjust and control power quality,thenormal and stable operation of transformer is of great significance to the safe and stable operation of the energyinternet. In order to accomplish this objective,status assessment of energy internet transformer b...
更多
Number of views:2585 Amount of downloads:1264
-
YANG Liping,WANG Haiyun,DING Dong,YU Xijuan,WANG Liyong,WU Honglin
Abstract: At present,there are some problems in line loss fault detection of electric quantity informationacquisition equipment,such as low detection rate,poor applicability and so on. An automatic line loss faultdetection method for electric quantity information acquisition equipment was proposed. By determining th...
更多
Number of views:2623 Amount of downloads:1259
-
YU Zhongan,CHEN Miao,DING Wensu,LIN Shangrong
Abstract: The traveling wave fault location of traditional double-circuit transmission lines are mainly studiedon the model with symmetric parameters. In order to solve the problem of traveling wave fault location of doublecircuit lines on the same tower with asymmetric parameters in engineering practice,a fault loc...
更多
Number of views:2690 Amount of downloads:1242
-
HUANG Xu,LIU Yichao,ZHU Hanqing,LIU Yang
Abstract: The DC fault current calculation method of modular multilevel converter(MMC)is the key to studythe DC fault transient characteristics and isolate the fault point rapidly in VSC-HVDC grid. Firstly,aiming at twotypical MMC fault equivalent models,the topology and the capacitor voltage characteristics when th...
更多
Number of views:3294 Amount of downloads:1537