Manuscript details
Current location:Home >Manuscript details
Release date:2023-05-19 Number of views:815 Amount of downloads:925 DOI:10.19457/j.1001-2095.dqcd24107
Abstract: Oil spills from thermal power plants can pollute the drainage outlet,if not dealt with in time,it will
also pollute the river environment. Drainage outlet monitoring is from the angle of depression,therefore it is hard to identify accurately with the rectangular detection frame. Based on the image from the depression angle of the
drainage outlet at a power plant,an algorithm of parallelogram detection frame was proposed. The effect of the
characteristics of this parallelogram detection frame and error in angle detection on intersection-over-union(IoU)
was analyzed. Characteristics of two methods for angle detection,i.e. classification and regression were discussed.
Addressing the issue of angle classification,label smoothing based on exponential function was designed. For
detection of the interval angle between categories,the classification- regression detector was designed to study the
offset of angle interval. In the end,the improved classification cross-entropy loss function and IoU-Smooth L1 loss
were introduced for training. According to data concentration tests at the drainage outlet of the power plant,the
proposed method is of the best detection effect.
Key words: parallelogram dtection frame;power plant drainage outlet;exponential label smoothing;angle
classification-regression detector;environmental protection