XU Dacheng ,YIN Chunya ,ZHOU Jiayang ,LI Fengting ,LIU Jiangshan
Abstract:To mitigate the fatigue load generated by wind turbine participation in primary frequency regulation,a primary frequency regulation strategy considering the fatigue load of wind turbine was proposed based on themechanical dynamic response characteristics and control device operation characteristics of wind ...
更多
Number of views:3821 Amount of downloads:11341
-
OU Zhixin,LI Jixia,DENG Chunlan
Abstract: The reliability and stability of electric energy transmission in the power grid are the guarantee ofdriving safety,due to the impact of external interference fluctuations and current arcs on the power grid structure,its parameter acquisition and dynamic modeling become difficult. Firstly,the characteristic...
更多
Number of views:3818 Amount of downloads:15513
-
ZHA Haitao,XU Kexin,LI Xiaowen,LIU Bin
Abstract: Active power filter(APF)is one of the main ways to eliminate harmonic quality problems in powergrid,and LCL filter is commonly used to connect APF to power grid. In order to suppress the resonance problemcaused by LCL filter,active damping based on capacitor current feedback is a common method. Active damp...
更多
Number of views:3805 Amount of downloads:9425
-
ZHAN Chengkang,LI Xiaolu,LU Yiming,LIU Riliang,LI Congli
Abstract: With the access of large-scale distributed energy resources in active distribution network,thetraditional centralized control architecture system will not effectively deal with a large number of distributed unit,so it is necessary to study the optimal scheduling of distributed resource cluster in active di...
更多
Number of views:3792 Amount of downloads:9196
-
QIAN Xiao,MA Xiang,LÜ Leiyan,ZHANG Wenjie,WANG Ning,ZHI Yuemei
Abstract: Traditional power grid dispatching alarm algorithm has low alarm instruction operation efficiency,low power grid dispatching failure burst rate and high alarm error alarm rate,so the power grid dispatching alarmassociation rules and decision tree algorithm based on knowledge graph were proposed. The associ...
更多
Number of views:3789 Amount of downloads:8375
-
LI Jiangcheng,CHEN Xiaohua,LI Haitao,ZHU Zhixu
Abstract: Because the current method does not optimize the control parameters of flexible AC transmissiondevice,resulting in unsatisfactory control results,control delay and loss rise,a flexible AC transmission devicecontrol method based on multi-objective optimization was proposed. The basic working principle of fl...
更多
Number of views:3783 Amount of downloads:9132
-
WANG Chengliang,PAN Zhixin,ZHAI Xuefeng,XIAO Yuhua,LIU Yu
Abstract: The mathematical model of magnetic coupled resonant wireless power transfer(MCR-WPT)system based on LCC-S compensation topology was established. Meanwhile,the influence on the transmissionperformance of the system was analyzed from three aspects:operating frequency,compensating inductance andload impedance...
更多
Number of views:3780 Amount of downloads:7315
-
ZHANG Rui,XIAYan,HUANG Guiping,CHEN Renzhao,YANG Yili
Abstract:Aiming at the poor robustness and system vibration problem of asynchronous motors under thetraditional sliding mode control,a variability coefficient power exponent reaching law(VCPERL)was proposed todynamically change the control coefficients according to the position of the sliding mode surface,and the sl...
更多
Number of views:3779 Amount of downloads:11140
-
WANG Wenguang,QIU Shuming,BAI Yang,GAO Pengcheng,YU Shipeng
Abstract: Taking the steel rolling system improvement as an example,the design of 12-pulse parallel electriccontrol system of SIEMENS SINAMICS DCM 6RA80 in the steel rolling system was described in detail,as well asthe calculation and selection of main components,such as rectifier transformer,rectifier device and sm...
更多
Number of views:3766 Amount of downloads:9314
-
SHEN Zhangliang,CHEN Yini,LI Haomin,LIU Zihao,MA Hongzhong,GE Xuanhao
Abstract:A fault diagnosis model for isolation switches based on Markov transition field(MTF),catch fishoptimization algorithm(CFOA)improved pyramid vision transformer(PVT)was proposed to address theproblems of complex fault situations,strong noise in signal extraction,and insufficient feature extraction. Firstly,th...
更多
Number of views:3760 Amount of downloads:15207
-
TANG Aiwu,CHEN Tianyou
Abstract:In order to effectively adjust and control the motion amplitude of the flexible manipulator and avoidlarge deviation between the actual motion track of the flexible manipulator and the target track,a flexiblemanipulator motion track control system based on the combination of distributed control system(DCS)a...
更多
Number of views:3760 Amount of downloads:10517
-
FU Yang,SIMA Chao,TIAN Shuxin,CAI Pengcheng,GU Jiping,LIU Shu
Abstract: Expected fault screening of smart distribution network is an important basis for system security situation assessment. In order to comprehensively and accurately perceive the security risk of smart distributionnetwork,a micro-synchronous phasor measurement unit(μPMU)with real-time,synchronicity,accuracy an...
更多
Number of views:3758 Amount of downloads:8013
-
SHI Dongsheng,WANG Tao,QIU Shuming,WANG Wenguang,WANG Yubo
Abstract: Application of TAC1 series high performance high power inverter products of Tianjin ElectricResearch Institute on 20-high reversible mill was introduced.The common DC bus multi drive system consists ofactive infeed converter and inverter. Firstly,the device selection of the system and the calculation of tra...
更多
Number of views:3757 Amount of downloads:15092
-
WANG Hao,LIU Naisuo,MENG Chao,FAN Ronggui,GONG Junlin,GAO Lianyan
Abstract:In order to solve the problem that the electrical cabinet of the original production and injectionsystem in the same well has a low intelligence level and cannot realize remote monitoring,diagnosis,restart andmaintenance through the network,an intelligent control software for production and injection in the...
更多
Number of views:3744 Amount of downloads:17225
-
CHEN Shaoxiong,ZHANG Penghe,SONG Runan,XUE Yang,CHEN Ganchao
Abstract:Power safety is a critical issue related to the reliable supply of energy and the safety of people's livesand property. In recent years,electrical fire incidents have been frequent in China,and low-voltage AC fault arcdiagnosis,especially for series fault arcs,is difficult to apply to the complex domest...
更多
Number of views:3737 Amount of downloads:23141