ZHA Haitao,XU Kexin,LI Xiaowen,LIU Bin
Abstract: Active power filter(APF)is one of the main ways to eliminate harmonic quality problems in powergrid,and LCL filter is commonly used to connect APF to power grid. In order to suppress the resonance problemcaused by LCL filter,active damping based on capacitor current feedback is a common method. Active damp...
更多
Number of views:3625 Amount of downloads:9191
-
WANG Chengliang,PAN Zhixin,ZHAI Xuefeng,XIAO Yuhua,LIU Yu
Abstract: The mathematical model of magnetic coupled resonant wireless power transfer(MCR-WPT)system based on LCC-S compensation topology was established. Meanwhile,the influence on the transmissionperformance of the system was analyzed from three aspects:operating frequency,compensating inductance andload impedance...
更多
Number of views:3625 Amount of downloads:7107
-
OU Zhixin,LI Jixia,DENG Chunlan
Abstract: The reliability and stability of electric energy transmission in the power grid are the guarantee ofdriving safety,due to the impact of external interference fluctuations and current arcs on the power grid structure,its parameter acquisition and dynamic modeling become difficult. Firstly,the characteristic...
更多
Number of views:3618 Amount of downloads:15260
-
LI Jiangcheng,CHEN Xiaohua,LI Haitao,ZHU Zhixu
Abstract: Because the current method does not optimize the control parameters of flexible AC transmissiondevice,resulting in unsatisfactory control results,control delay and loss rise,a flexible AC transmission devicecontrol method based on multi-objective optimization was proposed. The basic working principle of fl...
更多
Number of views:3616 Amount of downloads:8931
-
QIAN Xiao,MA Xiang,LÜ Leiyan,ZHANG Wenjie,WANG Ning,ZHI Yuemei
Abstract: Traditional power grid dispatching alarm algorithm has low alarm instruction operation efficiency,low power grid dispatching failure burst rate and high alarm error alarm rate,so the power grid dispatching alarmassociation rules and decision tree algorithm based on knowledge graph were proposed. The associ...
更多
Number of views:3599 Amount of downloads:8124
-
FU Yang,SIMA Chao,TIAN Shuxin,CAI Pengcheng,GU Jiping,LIU Shu
Abstract: Expected fault screening of smart distribution network is an important basis for system security situation assessment. In order to comprehensively and accurately perceive the security risk of smart distributionnetwork,a micro-synchronous phasor measurement unit(μPMU)with real-time,synchronicity,accuracy an...
更多
Number of views:3594 Amount of downloads:7769
-
SHEN Zhangliang,CHEN Yini,LI Haomin,LIU Zihao,MA Hongzhong,GE Xuanhao
Abstract:A fault diagnosis model for isolation switches based on Markov transition field(MTF),catch fishoptimization algorithm(CFOA)improved pyramid vision transformer(PVT)was proposed to address theproblems of complex fault situations,strong noise in signal extraction,and insufficient feature extraction. Firstly,th...
更多
Number of views:3592 Amount of downloads:14886
-
WANG Wenguang,QIU Shuming,BAI Yang,GAO Pengcheng,YU Shipeng
Abstract: Taking the steel rolling system improvement as an example,the design of 12-pulse parallel electriccontrol system of SIEMENS SINAMICS DCM 6RA80 in the steel rolling system was described in detail,as well asthe calculation and selection of main components,such as rectifier transformer,rectifier device and sm...
更多
Number of views:3591 Amount of downloads:9034
-
XU Dacheng ,YIN Chunya ,ZHOU Jiayang ,LI Fengting ,LIU Jiangshan
Abstract:To mitigate the fatigue load generated by wind turbine participation in primary frequency regulation,a primary frequency regulation strategy considering the fatigue load of wind turbine was proposed based on themechanical dynamic response characteristics and control device operation characteristics of wind ...
更多
Number of views:3573 Amount of downloads:10977
-
王德明,李英量,贾俊辉,解晨,王语园
Abstract: The conventional overcurrent protection is ineffective in isolating faults in microgrids due to the lowfault current level contributed by distributed generations(DGs). Because of its high agility and adaptability,themeasured impedance-based protection schemes are considered as common alternatives to detect...
更多
Number of views:3568 Amount of downloads:9157
-
ZHANG Rui,XIAYan,HUANG Guiping,CHEN Renzhao,YANG Yili
Abstract:Aiming at the poor robustness and system vibration problem of asynchronous motors under thetraditional sliding mode control,a variability coefficient power exponent reaching law(VCPERL)was proposed todynamically change the control coefficients according to the position of the sliding mode surface,and the sl...
更多
Number of views:3564 Amount of downloads:10873
-
TANG Aiwu,CHEN Tianyou
Abstract:In order to effectively adjust and control the motion amplitude of the flexible manipulator and avoidlarge deviation between the actual motion track of the flexible manipulator and the target track,a flexiblemanipulator motion track control system based on the combination of distributed control system(DCS)a...
更多
Number of views:3563 Amount of downloads:10244
-
XU Changbao,DING Jian,SONG Hongjian,PAN Chengda, SUN Pengbo,WANG Qihua,CHEN Hui
Abstract: An optimization method was proposed to layout electric vehicle charging facilities consideringpower quality constraints. A comprehensive power quality index model considering the average value of nodalthree-phase unbalance degree and the maximum value of nodal voltage deviation was established. Meanwhile,t...
更多
Number of views:3556 Amount of downloads:8787
-
WANG Hao,LIU Naisuo,MENG Chao,FAN Ronggui,GONG Junlin,GAO Lianyan
Abstract:In order to solve the problem that the electrical cabinet of the original production and injectionsystem in the same well has a low intelligence level and cannot realize remote monitoring,diagnosis,restart andmaintenance through the network,an intelligent control software for production and injection in the...
更多
Number of views:3543 Amount of downloads:16919
-
YIN Li,SHENG Junjie,YUAN Jie,FENG Yanjun
Abstract:In the context of carbon neutrality,an optimal pricing strategy for electric vehicle charging stationsconsidering carbon emissions was proposed. Firstly,a price response characteristic model of electric vehicle userswas constructed. Secondly,an optimal pricing model with the lowest carbon emission,the minim...
更多
Number of views:3539 Amount of downloads:13494