QU Bo,LI Xin,XIANG Xingyao,ZHANG Ping,WANG Dan
Abstract:A microgrid optimization scheduling model considering dynamic network reconstruction wasproposed for the parallel and off grid scheduling problem of microgrids. The proposed model was based on Bendersdecomposition and decomposes the optimal scheduling problem of microgrids into a grid-connected operationmas...
更多
Number of views:2159 Amount of downloads:7675
-
ZHOU Zhifeng,ZHU Wen,XIAWei,FANG Wenchong,HE Chaolin
Abstract: Under the background of energy internet,due to the access of massive sensor nodes,the amount and types of data in energy internet have increased dramatically,and centralized data processing has a great impact on the updating of substation drawing model. Therefore,a control measure of automatic updating of ...
更多
Number of views:2818 Amount of downloads:7650
-
ZHANG Baorui,WANG Jingtao,TAN Yao,WANG Zhiguang,LI Tang,SHI Yang
Abstract:Accurate short-term electrical load forecasting is of great significance for the design andoptimization scheduling of integrated energy systems(IES). However,the load data in real integrated energysystems are low-quality and fluctuating,so the forecasting accuracy of existing prediction models is low. A sho...
更多
Number of views:2462 Amount of downloads:7625
-
SUN Xiangfei,LI Ping,DA Guangjun,DOU Xiaochang
Abstract:Due to the large rotational inertia of synchronous machines,frequency changes caused by faults areminimal. In contrast,new energy systems have smaller rotational inertia,which can result in more significantfrequency variations during faults. These larger frequency fluctuations inevitably lead to changes in ...
更多
Number of views:1471 Amount of downloads:7619
-
CHEN Chen,DONG Pingxian,SONG Xiaofan,GUO Fang,QI Huanruo,DU Xiaotong
Abstract:After the distributed wind farm stations are integrated into the distribution network,due to thecharacteristics of wind farm short-circuit current amplitude control and frequency offset,the traditional three-stagecurrent protection of distribution network is difficult to accurately identify the fault on the...
更多
Number of views:2328 Amount of downloads:7618
-
TIAN Kai,YU Zhibin,YUAN Yuan,CHU ZiLin,CHEN Yujie,SUN Chuanjie
Abstract: A test method was proposed that can evaluate the ultimate power output capability of large capacityIGCT three-level converter. Based on synchronous symmetrical PWM modulation and temperature estimationmodel,the power experiment of IGCT three-level converter was carried out,which can test the equipment capa...
更多
Number of views:3104 Amount of downloads:7589
-
SUN Zhenqin,QU Jianhua,ZHANG Zhenzhen,QUAN Xiao,LI Hongbin,TAN Peng
Abstract: In order to improve the measurement accuracy of the position and speed closed-loop of the brushlessDC motor,which is currently used in the attitude control actuator,a new cumulative pulse M/T method wasproposed,based on incremental off-axis magnetic encoder(AS5304A)and TMS570 chip internal integratedenhance...
更多
Number of views:2576 Amount of downloads:7538
-
ZHUANG Gewei,GU Zhen ,FENG Xiuqing ,DUANYan
Abstract: Automatic verification system of smart meter may be abnormal in the long-term operation process,but the regular manual detection method can not timely learn the risk information,shortening the period of manual inspection will reduce the work efficiency of automatic verification. In most cases,the sample da...
更多
Number of views:3849 Amount of downloads:7490
-
LI Ning,LIU Ming,ZHANG Changjie,ZHANG Chenglin
Abstract:At present,the traditional passive filter in on-board charger(OBC) has poor low-frequencyperformance,an active feedback loop was added to the traditional on-board charger passive filter,a design method of on-board charger electromagnetic interference(EMI)hybrid filter based on current sensing and current in...
更多
Number of views:2749 Amount of downloads:7465
-
SUN Heyu,JI Baowei,WEI Yushan,FANG Weihan,WANG Yangyang
Abstract:In response to the problem of slow response speed of main steam pressure in the coordinated controlsystem of thermal power units,the control effect of the coordinated control system was improved by blowing outsome of the stored powder in the pulverizing system. Based on the traditional milling system model,...
更多
Number of views:2289 Amount of downloads:7450
-
CHENG Liang,DUAN Pengyang,SU Hongbang,TIAN Shengjuan,QI Xiaoxuan,YAN Shengping
Abstract:In the background of a high proportion of new energy source connected to grid,the phenomenon ofnew energy interface inverters being connected to the grid through long-distance AC lines is becoming increasinglysignificant. The traditional vector controlled weak grid connected voltage source converter(VSC)bas...
更多
Number of views:2605 Amount of downloads:7431
-
DING Jinjin,PENG Bo,ZHANG Feng,MAO Xun
Abstract:To address the large inrush current during the switching of a virtual synchronous generator(VSG)from off-grid to grid-connected,and the stability issues of traditional pre-synchronization schemes,a controlmethod for the phase-locked loop(PLL)pre-synchronization unit to be cut off in non-grid-connected time ...
更多
Number of views:1454 Amount of downloads:7407
-
LI Linwei,FU Zhimin,CHEN Mingfan,HE Lipeng,QIN Dan,HUANG Lige,CHENG Xi
Abstract: With the opening of the electricity market,the scattered and high idle rate of distributed energystorage has realistic conditions to participate in the aggregation and reuse,and the aggregation process caneffectively improve the efficiency of the power grid. The electric vehicles were taken as a typical re...
更多
Number of views:3510 Amount of downloads:7406
-
CAI Weiliang,CHENG Haifeng,PAN Zhixuan,CHENG Jin,DAI Mingli
Abstract: The grid connection of doubly-fed induction generator(DFIG)leads to the reduction of systemequivalent inertia and primary frequency regulation capacity. With the increase of DFIG grid connection scale,theproblem of system frequency regulation becomes more and more serious. In view of this problem,frequency...
更多
Number of views:2482 Amount of downloads:7405
-
ZOU Jia,ZHANG Jianqiao,JI Chengchun
Abstract: Aiming at the problem that the accuracy of the speed estimation of the traditional model referenceadaptive system(MRAS)method without speed sensor decreases after the speed load mutation in the low speedrange,a speed identification method based on the combination of back propagation(BP)double-layer artific...
更多
Number of views:2174 Amount of downloads:7405