Abstract: A test method was proposed that can evaluate the ultimate power output capability of large capacity
IGCT three-level converter. Based on synchronous symmetrical PWM modulation and temperature estimation
model,the power experiment of IGCT three-level converter was carried out,which can test the equipment capacity
under different load power factors and reversible operation,and achieve accurate evaluation of power device
temperature rise. This method uses PWM pulse width real-time adjustment to change the voltage difference
between the two ends of the load inductor. Compared with the general synchronous modulation method,which
directly changes the angle or voltage of the table lookup,this method further reduces the current ripple and makes
the test current closer to the actual situation.
Key words: three-level converter;integrated gate commutated thyristors(IGCT);power test;synchronization
modulation