XU Yelin,LU Xinqiang,ZHAO Ang,MA Li
Abstract: A cooperative control method for multi-port energy routers in distributed distribution networks wasproposed. Under the premise of power balance and bus voltage stability,seamless switching of various workingmodes of multi-port energy routers was realized to ensure the security and stability of distribution...
更多
Number of views:2887 Amount of downloads:8275
-
ZHAO Faping,SHE Yanjie,SUN Huanyu,BU Xiangzhou,BAI Tao
Abstract:A sliding mode linear self disturbance rejection control strategy was proposed to address the outputvoltage fluctuations caused by sudden load changes,changes in DC bus voltage,disturbance addition,and otherdisturbances in three-phase interleaved parallel DC-DC converters. Firstly,a mathematical model of th...
更多
Number of views:1905 Amount of downloads:8273
-
ZHANG Junkun,LEI Ertao,JIN Li,MA Kai,XIA Chenyang,WANG Xirui
Abstract:The rapid development of modern power electronics technology promotes the insulated gate bipolartransistor(IGBT)wide range of applications in the AC motor drive,inverter,switching power supply and newenergy industry. In the application process of IGBT,due to the complex and varied circuit topology and syste...
更多
Number of views:2786 Amount of downloads:8260
-
LI Lingqi,CHENG Zhijiang,GUO Shaokang,XIAO Shihao ,CHEN Xingzhi
Abstract: Aiming at the problem of wind abandonment caused by the contradiction between wind and heatduring the winter heating in the Three-north areas of China,a scheduling strategy for electric heating combinedsystem considering wind power consumption was proposed. Firstly,the "power determined by heat" constraint...
更多
Number of views:2377 Amount of downloads:8258
-
GUO Dengke,MI Wentao,ZHUANG Feihu,XU Yiduan,FAN Ruini
Abstract: According to the requirements of quickly and reasonably formulating load transfer measures afterdistribution network failure at this stage,a reliability evaluation scheme for fault transfer based on K-fold verification was introduced. Square up various power supply modes,according to the energy balance equ...
更多
Number of views:5442 Amount of downloads:8257
-
DONG Yi,ZHOU Yufei,LIU Shuai,WANG Yingying
Abstract: The coupling coefficient of the loosely coupled transformer in the inductively coupled wirelesspower transmission(ICPT)system is a key parameter affecting the conversion efficiency of the wireless energytransmission system. To improve the coupling coefficient,an equivalent magnetic circuit model was establ...
更多
Number of views:3719 Amount of downloads:8247
-
GAO Ruiteng,WANG Shuhong,WU Hao,LI Jiabin,CAO Jianwen,WU Pan,ZHANG Ailing
Abstract: A no-load grid-connected voltage phase control method of the brushless doubly-fed inductiongenerator(BDFIG)based on the control winding flux was proposed,the control system structure block diagram was constructed according to the mathematical model and control strategy of BDFIG. The hardware circuit of the...
更多
Number of views:4339 Amount of downloads:8241
-
MENG Chao,WANG Lianzhi,XIE Min,FU Yichao
Abstract: As the existing system fails to evaluate the process of pushing the power grid dispatch controlinstructions,the push delay and energy loss increase. A feature selection-based automatic push system for power grid dispatch control commands was proposed.According to the characteristics of power grid dispatch ...
更多
Number of views:3269 Amount of downloads:8238
-
HU Xiaoyu,ZHOU Yuanxiang,CHEN Jianning,ZHAO Yunzhou,LIU Jun
Abstract: As a new type of insulating oil in the power industry,natural gas insulating oil is excepted to solvethe bottleneck problem of high-quality transformer oil's insufficient supply in the future. However,its electricalparameters including partial discharge withstand strength and sweep frequency spectrum c...
更多
Number of views:4081 Amount of downloads:8230
-
LIU Jinchao,DUAN Hongmin,WU Letao,LIU Ligang,XU Chao
Abstract: Aiming at the phenomenon of pressure relief and deflagration caused by the faults of oil-immersedtransformer,a logic was proposed that the transformer can keep self-maintained running when faults occurred,and according to the logic,a scheme of oil circuit equipment was designed. The above logic and the sch...
更多
Number of views:5943 Amount of downloads:8227
-
ZHANG Xiangqian,CHE Chaochang,LI Fengsheng,YU Shipeng,LEI Hui
Abstract: As an important part of power electronic power conversion device,auxiliary power supply is facedwith the application demand of high voltage and wide range in DC transmission,solar power station,wind powerstation and other systems. Aiming at the problems of switch stress,cost and efficiency caused by high v...
更多
Number of views:2726 Amount of downloads:8223
-
MA Junchao,WANG Chenxu,SUN Dan,PENG Yan,ZHANG Zeyu,YANG Ying
Abstract:In response to the potential frequency secondary drop problem of direct-drive wind power systemsin the scenario of continuous frequency drop faults in the power grid,the principle of primary frequency regulationof direct-drive wind power systems was analyzed. A primary frequency regulation control strategy ...
更多
Number of views:2367 Amount of downloads:8217
-
LIU Lingshun,LI Yongheng,YAN Hongguang
Abstract: A nine-switch converter space vector pulse width modulation(SVPWM)algorithm was proposedbased on the dual Y shift 30° permanent magnet synchronous motor(PMSM)voltage vector. Compared with thebiggest four vectors of the twelve-switch converter SVPWM algorithm,the proposed algorithm not only reducesthree swi...
更多
Number of views:2534 Amount of downloads:8213
-
LI Mingyang,NIU Pingjuan,LI Yuhong,LI Ying,SUI Yu
Abstract: The offset characteristics of transmitting and receiving coils manufactured by different wirelesselectric vehicle manufacturers are a critical issue to ensure the interconnection of domestic and international vehiclecharging. The 3.7 kW wireless energy transmission system was modeled and the SS-type topolo...
更多
Number of views:4829 Amount of downloads:8205
-
CHEN Yong,LI Jianbiao,CHEN Jianfu,PEI Xingyu,WU Hongyuan,HUANG Chunyu
Abstract:The characteristics of the DC side of the DC distribution network are multi bus cascades,multipleconverters,and strong coupling of the buses,which can easily cause harmonic resonance and threaten the safeoperation of system equipment.Aims at the problem of unclear resonance interaction and harmonic transmis...
更多
Number of views:2519 Amount of downloads:8204