DING Chaohui,YAO Fei,JANG Jun,GAO Ang,SHAO Gao
Abstract:The traditional predictive current control for three-phase LCL grid connected inverters has theproblems of large steady-state ripple and unstable switching frequency,which is not conducive to the quality of grid connected current and the design of filters. Therefore,an improved three vector fixed frequency ...
更多
Number of views:797 Amount of downloads:1577
-
FAN Peilin,HU Pengtao,XUE Jianli,LIU Zheng,HUANG Jinming
Abstract:Voltage source converter (VSC) is prone to low-frequency oscillations of 100~101Hz whenconnected to weak AC power grids. The mechanism of improving the control strategy of VSC on the traditionalinverter side to suppress low-frequency oscillations(LFO)in the AC power grid is to transfer the oscillations from...
更多
Number of views:753 Amount of downloads:1574
-
ZHU Yuanzhe,WANG Ling,WU Zhengrong,LÜ Hong,XIAO Fan
Abstract:In order to further improve the output performance and efficiency of the converter,a grid-connectedconverter based on heterogeneous device mixing was proposed,referred to as heterogeneous grid-connectedconverter(HGCC). The HGCC consists of two half-bridge modules based on SiC MOSFET devices,which arecross-c...
更多
Number of views:888 Amount of downloads:1570
-
SUN Mengen,GONG Haiming,ZHAO Jie,SUN Rongrong,LU Huiwen,WANG Hui
Abstract:Accurate topology and line parameter information is the basis of state estimation and securitycontrol of distribution network. Affected by the performance of collection terminals and environmental factors,themeasurement error of metering equipment often deviates from Gaussian distribution. Higher requiremen...
更多
Number of views:819 Amount of downloads:1561
-
SHI Kun,CHEN Songsong,CHEN Xuejie,CHEN Zhaorui,YAN Huaguang,WU Yingjun
Abstract:New energy has obvious volatility and anti-peak-shaving characteristics,and the integration of largescale new energy into the power grid poses challenges to the peak-shaving. Hydrogen energy has a good potential for application as a potential peak-shaving resource. A multi-time scale peak-shaving scheduling...
更多
Number of views:978 Amount of downloads:1561
-
FANG Lei,XU Jun,ZHAO Yi,XING Xiaofan,MAO Huan
Abstract:The traditional technical line loss prediction method of low voltage station area has some problems,such as relatively extensive calculation,requiring underlying physical topology,and relying on influencecharacteristic data. In recent years,a technical line loss and meter error joint estimation technical ro...
更多
Number of views:786 Amount of downloads:1560
-
XIAO Quan,ZHOU Xiaoshan,WANG Ruiqing,LIU Yuqi,ZHAO Xianyuan
Abstract: The excitation control module of synchronous generator is the key equipment for power productionand safe operation,and the localization rate of its key materials is low. Based on the control performance of thesynchronous generator excitation control module,starting from the research of chip independent con...
更多
Number of views:1477 Amount of downloads:1557
-
NIU Zongxian,FAN Bo,FU Yulin,WANG Chunguang,WU Xiaodan,YANG Chenhui
Abstract: Under traditional PI parallel control strategies,synchronous control systems of multi-motor rigidconnection structure have the problem of unbalanced motor torque output,and there is even a serious risk of shaftbreakage. Taking the rigid connection structure of multi-motor gear transmission as the research ...
更多
Number of views:1341 Amount of downloads:1556
-
LÜ Zhengyu,ZHOU Liang
Abstract: In the process of controlling the voltage of active distribution network,there are problems of poorvoltage control effect and low efficiency. A two-stage automatic voltage control method of active distributionnetwork considering load measurement was proposed. Using the probability density function (PDF) cu...
更多
Number of views:1350 Amount of downloads:1551
-
CHEN Biao,HAN Zhongxiu,MA Liqiang,ZHANG Renhe
Abstract:The back-to-back active neutral-point-clamped(ANPC)converter,as the core component of theunified power flow controller of the distribution network,is widely used for the flexible closed-loop operation.However,the ANPC converter has more switching devices and commutation paths,which significantly increasesth...
更多
Number of views:793 Amount of downloads:1547
-
LI Ning,LIU Ming,ZHANG Changjie,ZHANG Chenglin
Abstract:At present,the traditional passive filter in on-board charger(OBC) has poor low-frequencyperformance,an active feedback loop was added to the traditional on-board charger passive filter,a design method of on-board charger electromagnetic interference(EMI)hybrid filter based on current sensing and current in...
更多
Number of views:1294 Amount of downloads:1547
-
YANG Zhaohui,WEI Huadong,HE Liuqing,ZHANG Hao,PENG Guoping,SHI Ben
Abstract:Aiming at the problem of large switching loss of modular multilevel converter(MMC),startingfrom the switching frequency optimization strategy,the existing switching frequency optimization strategy wasimproved,and the accurate analytical formula of sub-module capacitor voltage based on the real-time value of...
更多
Number of views:799 Amount of downloads:1546
-
MA Junchao,WANG Chenxu,SUN Dan,PENG Yan,ZHANG Zeyu,YANG Ying
Abstract:In response to the potential frequency secondary drop problem of direct-drive wind power systemsin the scenario of continuous frequency drop faults in the power grid,the principle of primary frequency regulationof direct-drive wind power systems was analyzed. A primary frequency regulation control strategy ...
更多
Number of views:820 Amount of downloads:1545
-
A Sileng,WANG Peng,YAN Xiaomeng,MIAO Zhu,HOU Jinxiu,ZHAO Jiadong
Abstract:As an important feature of the future power system,the penetration of a high proportion ofrenewable energy sources significantly enhances the uncertainty of power system operation. The probabilistic loadflow calculation,compared with the conventional tidal current calculation,can fully consider the influenc...
更多
Number of views:1023 Amount of downloads:1544
-
ZHU Qing,JI Cheng
Abstract:The massive access of 5G base stations has injected new vitality into the low-carbon development ofintegrated energy system(IES). By stimulating 5G base stations to participate in demand response andincorporating them into the scheduling framework of IES,energy saving and emission reduction of IES can beeff...
更多
Number of views:923 Amount of downloads:1544