LI Weiye,GONG Yifan,XU Wei,LUO Yinglu,HE Mingjie
Abstract: As a new type of compressor,linear compressor has the advantages of high efficiency,smallvolume,low noise and little vibration. However,in order to give full play to its advantages of high efficiency,it isnecessary to control the driving frequency to track its mechanical resonance frequency. According to t...
更多
Number of views:1611 Amount of downloads:3398
-
PENGTao
Abstract: The local leakage signal of high-voltage insulation equipment is weak and its characteristics are notobvious,which can only explain whether there is discharge. There is a phenomenon of missing judgment andmisjudgment in the actual positioning process,which is difficult to accurately locate the high-voltage...
更多
Number of views:1809 Amount of downloads:3379
-
CHENG Liang,DUAN Pengyang,SU Hongbang,TIAN Shengjuan,QI Xiaoxuan,YAN Shengping
Abstract:In the background of a high proportion of new energy source connected to grid,the phenomenon ofnew energy interface inverters being connected to the grid through long-distance AC lines is becoming increasinglysignificant. The traditional vector controlled weak grid connected voltage source converter(VSC)bas...
更多
Number of views:1534 Amount of downloads:3370
-
GENG Likai,HOU Juan,ZHANG Chunxiang,HU Wenying,LI Wenhua,LI Cuijuan
Abstract:Thermal and magnetic protection circuit breakers provided short circuit protection by instantaneoustripping devices. In the magnetic field formed by the coil with current,the moving armature and stationary coreovercomed the spring force and engage under the influence of electromagnetic force,thereby pushing...
更多
Number of views:1394 Amount of downloads:3357
-
WU Zhiheng,LIU Aimin
Abstract: The motor actuator used in circuit breaker has the advantages of simple structure,small dispersal ofaction and strong controllability,which provides the possibility for the switch contact of circuit breaker to followthe preset reference curve. The traditional control method can not adjust the parameters ac...
更多
Number of views:1746 Amount of downloads:3347
-
LIU Zhijian,ZI Chao,LI Pengcheng,GUO Cheng,LIU Jie,HUANG Wei
Abstract: Aiming at ultra-low frequency oscillation in power system caused by hydraulic turbine governingsystem,an additional damping control strategy for governing side was developed. Firstly,according to the damping torque method,the negative damping generated by the hydraulic turbine governing system was regarded...
更多
Number of views:1782 Amount of downloads:3335
-
GUO Jiahao,YANG Xiong,FANG Xin,LI Guanfei
Abstract: With the rapid development of primary and secondary fusion equipment,the detection efficiency ofthe traditional primary and secondary equipment testing method is very low,and it is no longer suitable for the new fusion switch equipment testing. In view of this,an integrated testing scheme for primary and s...
更多
Number of views:1523 Amount of downloads:3327
-
YAN Kun,GAN Jingfu,LIU Hongshun,SUI Yizhen,HE Pengkang
Abstract:A fusion prediction method was proposed to predict and correct the calculation deviation of the toptransformer oil temperature model in IEEE guideline,so as to realize the more precise prediction of the transformertop oil temperature(TOT). Firstly,the characteristics of the transformer TOT model and the ext...
更多
Number of views:1390 Amount of downloads:3310
-
WANG Qi,DONG Xinsheng,HE Shan
Abstract:To address the issue of transient overvoltage at the sending end of the wind farm caused by faults inconventional high-voltage direct current systems system,the impact mechanism of DC faults on transient voltagechanges at the sending end was analyzed. It was discovered that the reactive power surplus of the...
更多
Number of views:1350 Amount of downloads:3303
-
LI Yunwang,CHEN Junde,ZHANG Daping,SANG Yun,HAN Xiaolei
Abstract:An adaptive active arc suppression method based on S-transform correlation degree for distributionnetwork unidirectional grounding was proposed to effectively eliminate single-phase grounding fault arc indistribution network and improve power system stability. The time series data of zero-sequence current o...
更多
Number of views:1611 Amount of downloads:3294
-
LIU Hao,WEI Lixin,YOU Lichun
Abstract: Due to the particularity of its application,offshore drilling rig has higher requirements for thestability and control accuracy of the control signal. Aiming at the situation that the signal in the electronic controlsystem of offshore drilling rig is greatly disturbed by noise,a PID control signal optimiza...
更多
Number of views:1699 Amount of downloads:3251
-
LIU Fusuo,DING Rui,WANG Yu,CHENG Shuo,WANG Qi,HUANG Xifang
Abstract:In order to solve the DC over-voltage problem caused by surplus power when short circuit faultoccurs in the recipient grid of offshore wind power via voltage source converter high voltage direct currenttransmission(VSC-HVDC)delivery system,a joint fault ride-through strategy based on surplus power allocatio...
更多
Number of views:1164 Amount of downloads:3250
-
JIANG Xuejiao,ZHANG Changqing,QIN Gang,ZHONG Lei,ZHOU Chaojun,CHEN Yupei
Abstract:In order to balance the output difference between renewable energy and load in the activedistribution network and reduce the budget cost and user purchase cost,an optimal dispatching method ofdistributed generation units in the active distribution network based on power demand side response was proposed.On ...
更多
Number of views:1423 Amount of downloads:3237
-
LI Wei,LI Yingqi,HOU Leihao,LI Junpeng,LIU Dejian
Abstract:The main circuit faults of the four-quadrant rectifier and the corresponding influences were analyzedand summarized,focusing on the analysis of the voltage and current parameter equations in the pre-chargingprocess of the intermediate DC link,and the estimation method of the converter input current and the ...
更多
Number of views:1278 Amount of downloads:3204
-
HUANG Licai,YANG Xu,ZHANG Jing,LUO Chuanxian,CHEN Jia,ZHANG Guozhi
Abstract:In view of the frequent occurrence of omissions and false alarms of partial discharge insulationdefects in on-site gas insulated switchgear(GIS),the partial discharge multi-source detection test platform was built by using true GIS to carry out the intermittent discharge test of metal contamination defect o...
更多
Number of views:1269 Amount of downloads:3071