Download ranking
Current location:Home >Download ranking
-
XU Changbao,DING Jian,SONG Hongjian,PAN Chengda, SUN Pengbo,WANG Qihua,CHEN Hui
Abstract: An optimization method was proposed to layout electric vehicle charging facilities consideringpower quality constraints. A comprehensive power quality index model considering the average value of nodalthree-phase unbalance degree and the maximum value of nodal voltage deviation was established. Meanwhile,t...
更多
Number of views:1973 Amount of downloads:1040
-
ZHA Haitao,XU Kexin,LI Xiaowen,LIU Bin
Abstract: Active power filter(APF)is one of the main ways to eliminate harmonic quality problems in powergrid,and LCL filter is commonly used to connect APF to power grid. In order to suppress the resonance problemcaused by LCL filter,active damping based on capacitor current feedback is a common method. Active damp...
更多
Number of views:1207 Amount of downloads:1039
-
LI Peiying,XIA Jiakuan,WAN Chengchao
Abstract: In view of the mechanical vibration of the manipulator joint servo system due to the existence offlexible links such as harmonic reducer and toothed belt,a mathematical model considering the change of stiffnesscoefficient and large reduction ratio was established,the mechanism of mechanical resonance was a...
更多
Number of views:1242 Amount of downloads:1035
-
ZHANG Feifei,ZHANG Jun,WU Long,WU Xiaohui,XUE Zhanbo
Abstract: In order to solve the problems of false alarm rate and missing alarm rate in the traditional faultdetection method of substation primary equipment,a fault detection method of substation primary equipment based on deep convolution neural network was proposed. The substation primary equipment image and scene...
更多
Number of views:1868 Amount of downloads:1025
-
CHEN Linghan,LU Jia
Abstract: As the hub node in the energy internet,the transformer can adjust and control power quality,thenormal and stable operation of transformer is of great significance to the safe and stable operation of the energyinternet. In order to accomplish this objective,status assessment of energy internet transformer b...
更多
Number of views:2251 Amount of downloads:1024
-
QIAN Xiao,MA Xiang,LÜ Leiyan,ZHANG Wenjie,WANG Ning,ZHI Yuemei
Abstract: Traditional power grid dispatching alarm algorithm has low alarm instruction operation efficiency,low power grid dispatching failure burst rate and high alarm error alarm rate,so the power grid dispatching alarmassociation rules and decision tree algorithm based on knowledge graph were proposed. The associ...
更多
Number of views:1957 Amount of downloads:1023
-
YE Hai
Abstract: Flexible DC power grid is an important way for efficient transmission of various types of renewableenergy. How to design an efficient reclosing strategy to make it have the ability of rapid recovery after fault is a keyproblem to improve the stability of the whole AC/DC power grid. According to the working...
更多
Number of views:2178 Amount of downloads:1022
-
LI Jiangcheng,CHEN Xiaohua,LI Haitao,ZHU Zhixu
Abstract: Because the current method does not optimize the control parameters of flexible AC transmissiondevice,resulting in unsatisfactory control results,control delay and loss rise,a flexible AC transmission devicecontrol method based on multi-objective optimization was proposed. The basic working principle of fl...
更多
Number of views:1573 Amount of downloads:1019
-
YANG Liping,WANG Haiyun,DING Dong,YU Xijuan,WANG Liyong,WU Honglin
Abstract: At present,there are some problems in line loss fault detection of electric quantity informationacquisition equipment,such as low detection rate,poor applicability and so on. An automatic line loss faultdetection method for electric quantity information acquisition equipment was proposed. By determining th...
更多
Number of views:2218 Amount of downloads:1017
-
DAI Feng,CHEN Xuan,WANG Lixian,MA Hongzhong
Abstract: Partial discharge fault diagnosis and location of gas insulated metal enclosed transmission line(GIL)is of great significance for its internal insulation protection. Because GIL is fully enclosed structure,theexisting external detection method is not sensitive to the internal defect detection,so it is unab...
更多
Number of views:2002 Amount of downloads:1015
-
ZHUANG Gewei,GU Zhen ,FENG Xiuqing ,DUANYan
Abstract: Automatic verification system of smart meter may be abnormal in the long-term operation process,but the regular manual detection method can not timely learn the risk information,shortening the period of manual inspection will reduce the work efficiency of automatic verification. In most cases,the sample da...
更多
Number of views:2162 Amount of downloads:1009
-
LIU Juan,HU Xiaolei,TENG Yiyina,ZHANG Shiqi,ZHANG Zhe
Abstract: Hydrogen fuel cells air compressor is an important accessory of hydrogen fuel cell,but the high costcaused by its high energy consumption hinders the further development of hydrogen fuel cell. In recent years,theindustry has gradually adopted variable frequency drives to control the operation of hydrogen f...
更多
Number of views:946 Amount of downloads:1006
-
ZHANG Yi,CHANG Pengfei
Abstract: With the increasing penetration of large-scale wind and PV power within the power system,theywill inevitably participate in the load frequency contro(l LFC). Since the power output of wind and PV is unstable,which would affect the power balance of grid,thus cause unstable frequency. A LFC method based on d...
更多
Number of views:2322 Amount of downloads:1001
-
YU Zhongan,CHEN Miao,DING Wensu,LIN Shangrong
Abstract: The traveling wave fault location of traditional double-circuit transmission lines are mainly studiedon the model with symmetric parameters. In order to solve the problem of traveling wave fault location of doublecircuit lines on the same tower with asymmetric parameters in engineering practice,a fault loc...
更多
Number of views:2331 Amount of downloads:993
-
ZHAN Chengkang,LI Xiaolu,LU Yiming,LIU Riliang,LI Congli
Abstract: With the access of large-scale distributed energy resources in active distribution network,thetraditional centralized control architecture system will not effectively deal with a large number of distributed unit,so it is necessary to study the optimal scheduling of distributed resource cluster in active di...
更多
Number of views:1717 Amount of downloads:990