LI Junjun,LI Zhongqi,YI Jiliang
Abstract: Shared inverter can simplify the topology of the dual machines drive system under the traditional axiscontrol mode,reduce the volume and weight of the equipment. In view of the low voltage utilization rate of a single motor in the shared inverter drive system,which leads to the shortening of the constant p...
更多
Number of views:2317 Amount of downloads:1932
-
WANG Hao,LIU Naisuo,MENG Chao,FAN Ronggui,GONG Junlin,GAO Lianyan
Abstract:In order to solve the problem that the electrical cabinet of the original production and injectionsystem in the same well has a low intelligence level and cannot realize remote monitoring,diagnosis,restart andmaintenance through the network,an intelligent control software for production and injection in the...
更多
Number of views:713 Amount of downloads:1926
-
GAO Shanxue,YANG Xin,SHEN Wenbing,ZHONG Wei,ZHANG Shuai,WANG Min
Abstract: DC microgrid usually consists of a plurality of power electronic converters with feedback controlconnected to a common DC bus. Although the control loop design of each individual converter has a good stabilitymargin,the interconnection of multiple power and load converters can cause stability and performan...
更多
Number of views:2377 Amount of downloads:1915
-
NIU Shengsuo,CHENG Bo,LI Jinbo,LÜ Linfei,FU Xiulai
Abstract: Avoltage disturbance detection method based on mathematical morphological filtering and derivationdq transformation was proposed. Firstly,in order to reduce the interference of pulses,harmonics and other noises in the signals to be detected,a composite morphological filter was constructed based on adaptive...
更多
Number of views:2262 Amount of downloads:1913
-
LIU Ronghui,MA Tiantian ,SUN Gaiping
Abstract:The potential dispatchable resources of electric power,heat,cool and gas in the integrated energysystem(IES)are important contributors to reduce the operating cost of IES. In order to guarantee the customersatisfaction while reducing operating cost of IES,a IES day-ahead optimal dispatch model considering a...
更多
Number of views:2301 Amount of downloads:1911
-
TONG Zhan' anxin,SU Jianhui,ZHANG Jian,DU Yan
Abstract: The requirements for wireless charging of automated guided vehicle(AGV)batteries are low voltageand high current,full-wave-synchronous-rectification(FWSR)can improve efficiency and reduce costs. Firstly,AGV wireless charging topology and working principle were introduced in detail. Secondly,aiming at the p...
更多
Number of views:2368 Amount of downloads:1910
-
TANG Jiayuan,ZHAO Wenbin,LU Wu,GAO Yuan
Abstract: Under the electric power market environment,the key to achieve the joint operation of virtual powerplants lies in the profit distribution among the internal multi-subjects. To solve the impact of the final profitdistribution,which is caused by the uncertainty of the clean energy output of each main body in...
更多
Number of views:3715 Amount of downloads:1906
-
ZHAO Kuanxiang,YOU Jiawei,LIU Hongxun,LING Yuesheng,TIAN Rui
Abstract: The electrolytic capacitor is used as the energy storage element in the traditional LED power supply.The life of electrolytic capacitor is short which limits the life of LED power supply. In order to improve the servicelife of the power supply,a single-stage low switch stress structure was proposed on the ...
更多
Number of views:3960 Amount of downloads:1906
-
LI Yanlei,ZHANG Xiaoyang,LI Xiaoling,LIU Wei,WANG Gang,ZHOU Gaowei
Abstract: Because traditional methods have problems such as poor control stability and low control efficiencyin the process of using unmanned aerial vehicle(UAV)to check obstacles in transmission channels,a transmissionchannel unmanned aerial vehicle motor auto-disturbance rejection control technology based on extre...
更多
Number of views:3387 Amount of downloads:1905
-
SHI Zhibo,MENG Jie,HAN Yong,LI Xueping
Abstract: Due to the application of a large number of power electronic equipments on the aircraft,the aircraftpower supply network tends to be complicated,and thus there is an urgent need to effectively evaluate the powerquality of the power supply network. In order to evaluate AC power quality of aircraft,a compreh...
更多
Number of views:4260 Amount of downloads:1903
-
TAN Xiaomeng,LIU Jichun
Abstract: New energy with intermittent and uncertainty would seriously impact the operation reliability,especially in isolated multi-energy complementary generation system,and make the system face certain risks. Thus,reasonable system reserve is the key to avoid large risk loss in isolated island power system under ...
更多
Number of views:3894 Amount of downloads:1893
-
TANG Weifeng,WANG Changjiang
Abstract: In the motor controller of new energy vehicles,due to insufficient current capacity,high cost,andlimited heat dissipation capacity,parallel power devices are often used to extend current capability of power inverter for EV applications. Current imbalance can be caused by device parameter tolerances,parasit...
更多
Number of views:2345 Amount of downloads:1891
-
LIU Tong,YIN Zhonggang,BAI Cong,YUAN Dongsheng
Abstract: In order to improve the position sensorless control performance of permanent magnet synchronouslinear motor(PMSLM),a position sensorless control method based on disturbance compensated flux observer(DCFO)was studied. This method treats the notch filter as a disturbance observer and combines it with a feedb...
更多
Number of views:1364 Amount of downloads:1890
-
TIAN Kai,WANG Ziman,CHU Zilin,YU Zhibin,YUAN Yuan,SONG Peng
Abstract: A method to extract the equivalent thermal resistance parameters of double-sided water-cooledheatsink was proposed. Based on this method,the real-time calculation of junction temperature and overtemperature protection of integrated gate commutation transistor(IGCT)power device were implemented by the water...
更多
Number of views:3685 Amount of downloads:1885
-
ZHAN Chengkang,LI Xiaolu,LU Yiming,LIU Riliang,LI Congli
Abstract: With the access of large-scale distributed energy resources in active distribution network,thetraditional centralized control architecture system will not effectively deal with a large number of distributed unit,so it is necessary to study the optimal scheduling of distributed resource cluster in active di...
更多
Number of views:2140 Amount of downloads:1882