-
LI Jianjie,GAI Pengyu,WANG Lihua,ZHANG Jian,SUN Hongbo,XIN Chunqing
Abstract: In order to improve the optimal allocation of renewable energy in microgrid and reduce theuncertainty of source load in microgrid,a multi-objective coordinated scheduling optimization method for microgrid based on Pearson correlation coefficient meta-learning(PCC-ML)source load prediction was proposed. Fir...
更多
Number of views:2744 Amount of downloads:10086
-
CUI Qian,ZHOU Jiemin,DING Zhengdao,QIN Jina,GAO Yiqing,JIANG Pengchuan
Abstract:In order to solve the problem of overvoltage and overcurrent in the process of load sudden changefor ion thruster screen grid power supply,the phase shift pulse frequency modulation(PS-PFM)was used tostabilize the output voltage of the LLC resonant converter. When the sampling voltage is lower than the lowe...
更多
Number of views:2810 Amount of downloads:10075
-
KONG Fanting,WANG Yang,YANG Hao,CHEN Jian,LU Lin
Abstract: High-voltage/low-voltage prefabricated substation is short for“box substation”,its nature of savingenergy has been widely researched. The research have been from choosing components to optimizing structure. Agreat of improved products have swarmed into market. But there is neither a set of method to test l...
更多
Number of views:5041 Amount of downloads:10069
-
LI Xuan,DONG Yongle,HAI Hongye,JIN Zhao
Abstract: Under the background of smart grid,higher requirements are put forward for the management level of distribution network,and the traditional static model can not meet the application requirements of refined line loss and real-time scheduling. Based on low-voltage power grid topology identification and broad...
更多
Number of views:5844 Amount of downloads:10068
-
WANG Wenyuan,LUO Zhiwei,XIA Huan,CHEN Jie
Abstract:The modeling of distributed power sources in DC microgrids serves as the foundation for large-scalepower system simulations. However,the difficulty in obtaining electromagnetic parameters of diesel generatorshampers the accuracy of their electrical characteristic modeling. To address this issue,a data-drive...
更多
Number of views:2724 Amount of downloads:10055
-
SONG Zhuoran,LI Jianfeng,JIANG Tao,DENG Xinyang,LIU Yu
Abstract: There are parameter identification errors in the process of distribution network synchronousmeasurement configuration. The optimal configuration method of distribution network synchronous measurementdevice based on parameter identification accuracy was studied. Based on the measurement data of the synchron...
更多
Number of views:5011 Amount of downloads:10045
-
CHEN Ya′ai,LI Zixuan,ZHOU Jinghua,WU Jiewei
Abstract: As a three-level Boost AC/DC converter with unidirectional energy flow,the VIENNA rectifier iswidely used in electric vehicle charging systems and other occasions. The key to improve the power quality and thesystem reliability is the quality of control strategy. Therefore,the control strategy of the VIENNA ...
更多
Number of views:6592 Amount of downloads:10042
-
WU Han,HUANG Xinghua,QIAO Zhendong,FAN Yuanliang,ZHU Junwei,CHEN Jinyu
Abstract:Accurately estimating the state of health(SOH)of lithium-ion batteries is a crucial prerequisite forensuring the safe and stable operation of energy storage systems. The key to improving the accuracy of SOHestimation lies in the rational selection of health characteristics that can effectively reflect the s...
更多
Number of views:2384 Amount of downloads:10040
-
LIU Shiqi,WANG Yajing,MEI Yu,ZHANG Xiangke,SHI Yao,DOU Zhenhai
Abstract: In order to solve the problem of extracting harmonic parameters by noise interference Pronyalgorithm,a harmonic analysis method based on ensemble local mean decomposition(ELMD),singular valuedecomposition(SVD)and Prony was proposed. Firstly, the noisy signal was decomposed by ELMD,and thedemarcation point ...
更多
Number of views:5004 Amount of downloads:10036
-
DONG Lizhi,ZHAI Bingcong,WANG Kaifeng,JIA Xuecui
Abstract:When multiple energy storage units are connected to an energy storage station by the powerelectronic converter,the interaction and coupling effect bring challenges to the stable operation of the system. Thesmall-signal model of the parallel storage system was established. The stability analysis was carried ...
更多
Number of views:2525 Amount of downloads:10005
-
ZHAO Jianyong,LI Han,WU Min,MA Runsheng,ZHAO Wenqiang,YU Ziwei
Abstract: Firstly,the significance of impedance modeling for new energy power generation equipment wasanalyzed,and the existing impedance modeling methods were explained. Aiming at the problems of low flexiblematching degree,single disturbance signal,fixed disturbance frequency and the inability of real-time measure...
更多
Number of views:5644 Amount of downloads:9996
-
MIAO Yuntao,WANG Chengxian,LI Junda,GU Jiateng,ZHANG Zhenbin
Abstract:Model predictive control(MPC)is an effective control strategy for permanent magnet synchronousgenerators(PMSG)due to its fast dynamic response and multi-objective optimization capabilities. However,MPCrelies on accurate system models and sensor measurements. In practical conditions,parameter mismatch caused...
更多
Number of views:2552 Amount of downloads:9973
-
QIN Changfeng,YIN Jiang,SONG Shijie
Abstract:In order to solve the problem of parameter estimation in the high-performance control of squirrelcage asynchronous motor,a method for joint parameter identification of asynchronous motors with dual modelsbased on improved whale algorithm was proposed. This method can effectively identify the stator resistan...
更多
Number of views:2670 Amount of downloads:9970
-
CHEN Yaai,ZHAO Junwei,ZHOU Jinghua,ZHAO Xun
Abstract:Flexible substation based on AC/DC hybrid power distribution technology is a major trend for futuredistribution network development.It has attracted wide attention due to multiple functions such as itsmultiterminal interfaces for medium/low and AC/DC voltage flexible power flow control multi-modal energy inter...
更多
Number of views:6433 Amount of downloads:9957
-
HE Kun,WANG Can,ZHANG Kan,CHEN Kaiping,ZHU Hanqin,FU Zhiyu,XU Lei
Abstract: In the case of asymmetric faults in high voltage direct current(HVDC) transmission system,modular multilevel converter-battery energy storage system(MMC-BESS)has a longer state of charge(SOC)balancing process,uneven allocation of resources,easy to occur over modulation and other security problems,anew SOC ...
更多
Number of views:3920 Amount of downloads:9927