HUANG Xu,LIU Yichao,ZHU Hanqing,LIU Yang
Abstract: The DC fault current calculation method of modular multilevel converter(MMC)is the key to studythe DC fault transient characteristics and isolate the fault point rapidly in VSC-HVDC grid. Firstly,aiming at twotypical MMC fault equivalent models,the topology and the capacitor voltage characteristics when th...
更多
Number of views:5464 Amount of downloads:10286
-
HAN Jianfu,XIAO Chun,SONG Xiaobing,LU Jiansheng,WANG Feifei
Abstract: With the continuous advancement of China's energy Internet strategy,how to reduce the occurrenceof electricity theft has become a focus of research. The historical data of electricity consumption was processed andanalyzed,and the data of electricity consumption were processed and converted to realize t...
更多
Number of views:5442 Amount of downloads:9558
-
KONG Fanting,WANG Yang,YANG Hao,CHEN Jian,LU Lin
Abstract: High-voltage/low-voltage prefabricated substation is short for“box substation”,its nature of savingenergy has been widely researched. The research have been from choosing components to optimizing structure. Agreat of improved products have swarmed into market. But there is neither a set of method to test l...
更多
Number of views:5436 Amount of downloads:11075
-
SONG Zhuoran,LI Jianfeng,JIANG Tao,DENG Xinyang,LIU Yu
Abstract: There are parameter identification errors in the process of distribution network synchronousmeasurement configuration. The optimal configuration method of distribution network synchronous measurementdevice based on parameter identification accuracy was studied. Based on the measurement data of the synchron...
更多
Number of views:5404 Amount of downloads:11018
-
TIAN Kai,WANG Ziman,CHU Zilin,YU Zhibin,YUAN Yuan,SONG Peng
Abstract: A method to extract the equivalent thermal resistance parameters of double-sided water-cooledheatsink was proposed. Based on this method,the real-time calculation of junction temperature and overtemperature protection of integrated gate commutation transistor(IGCT)power device were implemented by the water...
更多
Number of views:5396 Amount of downloads:9642
-
ZHOU Zhen,PENG Yuanxiu,LIU Bin,LI Xiaowen,ZHA Haitao
Abstract: In the isolated island operation mode of microgrid,the output power of distributed generation unitsin the system is difficult to distribute reasonably due to the difference of output line impedance,which affects thestability of the system. In order to realize the reasonable distribution of power according ...
更多
Number of views:5394 Amount of downloads:12008
-
FANG Biwu,XIAO Liang ,SUN Cheng,CHEN Yiping,XUE Yanjun,ZHANG Deliang
Abstract: In order to improve the absorption capacity of clean energy and make full use of the peak regulationresources of each province,the peak regulation capacity of different types of power sources was studied,and aregional power grid optimization dispatching method considering the mutual aid of peak regulation ...
更多
Number of views:5391 Amount of downloads:10510
-
ZHANG Yexin,DENG Yunchuan,LIU Zhigang,ZHANG Yuting,CHEN Tao,HUANG Ke
Abstract: When the high-speed electric multiple units(EMUs)pass through the long downslope route,speedlimit is required to meet the safety of train operation,the regenerative braking energy generated in this process isreturned to the traction network and may threaten the safety of power supply. At present,there are ...
更多
Number of views:5389 Amount of downloads:11165
-
LI Qinzhao,ZHAO Xuemin
Abstract: When the microgrid is operating in island mode,the cascaded H-bridge(CHB)converter as aninterface device may need to be configured with a non-sinusoidal reference wave of pulse width modulation(PWM)when implementing auxiliary functions such as negative sequence compensation. In order to avoid overmodulatio...
更多
Number of views:5388 Amount of downloads:11434
-
HUANG Heyao,WANG Luyang,WU Jiaming,BAI Yang,DING Quan,BAI Hongshan
Abstract: Virtual synchronous generator technology can provide virtual inertia for the frequency stability ofmicrogrid,but there are a lot of asymmetric loads in the operation of microgrid. In order to compensate theunbalanced load and output three-phase symmetrical voltage and current,an improved control strategy b...
更多
Number of views:5379 Amount of downloads:10883
-
WANG Xing,TAN Peixiao,CHENG Zhijiang,MAWanqing,TIAN Bo
Abstract: Retired power batteries have poor parameter consistency,when they are used for energy storageafter series and parallel connections,the barrel effect is obvious and the failure rate is high. So the improved modular multilevel H-bridge converter(MMHC)distributed energy storage based on modular multilevel con...
更多
Number of views:5378 Amount of downloads:10433
-
LIU Shiqi,WANG Yajing,MEI Yu,ZHANG Xiangke,SHI Yao,DOU Zhenhai
Abstract: In order to solve the problem of extracting harmonic parameters by noise interference Pronyalgorithm,a harmonic analysis method based on ensemble local mean decomposition(ELMD),singular valuedecomposition(SVD)and Prony was proposed. Firstly, the noisy signal was decomposed by ELMD,and thedemarcation point ...
更多
Number of views:5374 Amount of downloads:11013
-
ZHANG Ao,DAI Linwang,MA Zhengyang,LI Shaolin,ZHANG Xueguang
Abstract: Doubly-fed wind turbine is easy to produce sub-synchronous oscillation in series compensation grid.Using virtual synchronous control structure to improve inertia and damping for grid may also lead to subsynchronous oscillation risk. In view of the causes of sub-synchronous oscillation,firstly,the double-fe...
更多
Number of views:5344 Amount of downloads:14439
-
XU Qiongguo,ZHANG Weitao,LIU Guangwei,ZHOU Bin
Abstract: Independent DC microgrid with distributed power supply and energy storage system plays animportant role in improving power supply reliability. The energy scheduling optimization of DC microgrid underdifferent operating modes was discussed,including diesel generator,fuel cell,micro gas turbine,photovoltaic,...
更多
Number of views:5340 Amount of downloads:12128
-
DING Yi1,LIU Shengzhong,WANG Xudong,HUO Xianxu,HU Zhigang,JIANG Fan
Abstract: The estimation method of state of health(SOH)of lead-acid battery based on chaotic particle swarmoptimization-Gaussian process regression(CPSO-GPR)was proposed. Firstly,the voltage and current curves of leadacid battery during charging process were investigated,and the characteristics of constant current c...
更多