WANG Xing,TAN Peixiao,CHENG Zhijiang,MAWanqing,TIAN Bo
Abstract: Retired power batteries have poor parameter consistency,when they are used for energy storageafter series and parallel connections,the barrel effect is obvious and the failure rate is high. So the improved modular multilevel H-bridge converter(MMHC)distributed energy storage based on modular multilevel con...
更多
Number of views:4345 Amount of downloads:5624
-
YAN Yuhao,ZHOU Buxiang,CHEN Shi,DONG Shen,LIU Zhifan,ZANG Tianlei
Abstract: At present,the focus of research on doubly fed induction generator(DFIG)high voltage ride through is a single high voltage fault.However,after DFIG low voltage ride through,due to the irrationality of the reactive power compensation strategy,a low/high voltage compound fault have be caused,which have a cer...
更多
Number of views:4343 Amount of downloads:6802
-
ZHANG Mao,CHENG Wenming,QIN Qin
Abstract: A set of container positioning system based on the laser radar measurement technology wasdesigned and realized to solve the problems of long service time,low efficiency and high labor intensity in therailway freight yard which caused by the manual operation of crane spreader alignment. The overall architec...
更多
Number of views:4343 Amount of downloads:5151
-
FANG Biwu,XIAO Liang ,SUN Cheng,CHEN Yiping,XUE Yanjun,ZHANG Deliang
Abstract: In order to improve the absorption capacity of clean energy and make full use of the peak regulationresources of each province,the peak regulation capacity of different types of power sources was studied,and aregional power grid optimization dispatching method considering the mutual aid of peak regulation ...
更多
Number of views:4330 Amount of downloads:5187
-
HUANG Xu,LIU Yichao,ZHU Hanqing,LIU Yang
Abstract: The DC fault current calculation method of modular multilevel converter(MMC)is the key to studythe DC fault transient characteristics and isolate the fault point rapidly in VSC-HVDC grid. Firstly,aiming at twotypical MMC fault equivalent models,the topology and the capacitor voltage characteristics when th...
更多
Number of views:4315 Amount of downloads:5523
-
DAI Yemin,LI Yukun,LIN Shunfu,BIAN Xiaoyan,LI Dongdong
Abstract: With the wide application of new energy grid connection technology,a large number of powerelectronic devices are connected to the power grid,and the power quality is affected by harmonic interaction. Aiming at the harmonic interaction problem of multi-inverter grid-connected system,the multi-input and mult...
更多
Number of views:4296 Amount of downloads:6611
-
WU Ming,LÜ Zhipeng,WANG Xin,YANG Wanli,ZHOU Shan,LIU Xiaojuan
Abstract: Multi-energy complementary DC micro-grid is of great significance to achieve sustainable energydevelopment. Based on the typical DC micro-grid with various energy forms including wind,solar,gas and battery,a multi-energy DC micro-grid operation control strategy considering the complementary inertia of gas ...
更多
Number of views:4282 Amount of downloads:5595
-
HUANG Heyao,WANG Luyang,WU Jiaming,BAI Yang,DING Quan,BAI Hongshan
Abstract: Virtual synchronous generator technology can provide virtual inertia for the frequency stability ofmicrogrid,but there are a lot of asymmetric loads in the operation of microgrid. In order to compensate theunbalanced load and output three-phase symmetrical voltage and current,an improved control strategy b...
更多
Number of views:4275 Amount of downloads:5315
-
ZHOU Zhen,PENG Yuanxiu,LIU Bin,LI Xiaowen,ZHA Haitao
Abstract: In the isolated island operation mode of microgrid,the output power of distributed generation unitsin the system is difficult to distribute reasonably due to the difference of output line impedance,which affects thestability of the system. In order to realize the reasonable distribution of power according ...
更多
Number of views:4257 Amount of downloads:5964
-
ZHANG Yexin,DENG Yunchuan,LIU Zhigang,ZHANG Yuting,CHEN Tao,HUANG Ke
Abstract: When the high-speed electric multiple units(EMUs)pass through the long downslope route,speedlimit is required to meet the safety of train operation,the regenerative braking energy generated in this process isreturned to the traction network and may threaten the safety of power supply. At present,there are ...
更多
Number of views:4235 Amount of downloads:5670
-
KONG Fanting,WANG Yang,YANG Hao,CHEN Jian,LU Lin
Abstract: High-voltage/low-voltage prefabricated substation is short for“box substation”,its nature of savingenergy has been widely researched. The research have been from choosing components to optimizing structure. Agreat of improved products have swarmed into market. But there is neither a set of method to test l...
更多
Number of views:4235 Amount of downloads:5579
-
SONG Zhuoran,LI Jianfeng,JIANG Tao,DENG Xinyang,LIU Yu
Abstract: There are parameter identification errors in the process of distribution network synchronousmeasurement configuration. The optimal configuration method of distribution network synchronous measurementdevice based on parameter identification accuracy was studied. Based on the measurement data of the synchron...
更多
Number of views:4231 Amount of downloads:5407
-
YANG Fan,HUANG He,LI Haiying,LI Dongdong,ZHAO Yao
Abstract: There are a lot of equipment operation rules in power equipment defect text,which can be mined bynatural language processing technology to provide guidance for equipment maintenance. Aiming at this situation,a defect text mining method based on enhanced representation through knowledge integration(ERNIE)pr...
更多
Number of views:4218 Amount of downloads:5718
-
LIN Bin,SHAO Haoshu,WANG Xiaohe,LI Hongke,CAI Xu
Abstract: With the increasing scale of wind farms,large scale wind farm is gradually shifting from onshorewind farm to offshore wind farm,squirrel cage induction generator(SCIG),which is the main type of offshore wind farm,has become the main research object of offshore wind farm dynamic characteristics. In order to...
更多
Number of views:4203 Amount of downloads:4901
-
XU Qiongguo,ZHANG Weitao,LIU Guangwei,ZHOU Bin
Abstract: Independent DC microgrid with distributed power supply and energy storage system plays animportant role in improving power supply reliability. The energy scheduling optimization of DC microgrid underdifferent operating modes was discussed,including diesel generator,fuel cell,micro gas turbine,photovoltaic,...
更多
Number of views:4197 Amount of downloads:6157