Browse ranking
Current location:Home >Browse ranking
-
YAN Hao,BA Sang,GU Yi
Abstract: Insulation failure can cause motor turn-to-turn,phase-to-ground and ground-to-ground faults,ranging from equipment downtime,or endangering personal safety,resulting in catastrophic consequences. In order to be able to carry out online sensitive monitoring of the deterioration state in the early stage of tu...
更多
Number of views:5658 Amount of downloads:10075
-
CHEN Zhixiu,LIU Yang,ZHANG Hanshu,XIAYe,WANG Hao,LIU Xin
Abstract: In the period of high and new technology development,the application of SiC and other newsemiconductors promotes the development of PCB design toward integration and high efficiency. The new ideas were provided for PCB design optimization from two aspects of high frequency and high density. Among them,ther...
更多
Number of views:5657 Amount of downloads:9662
-
LIU Xiaodong,SUN Lunan,LIU Yawei,GUAN Peng,RONG Xifeng
Abstract: In order to meet the needs of the testing laboratory's task scheduling and process design functions,the new applications were developed based on the existing laboratory information management system,such asscheduling system and process designer. According to the type and priority of the test task,the t...
更多
Number of views:5626 Amount of downloads:8994
-
ZHOU Xuesong,XIE Bingjie,MAYoujie,LIU Qian
Abstract: To effectively solve the problem of stable control for DC-bus voltage in the independent photovoltaicenergy storage system under multi-source disturbances,a bidirectional DC-DC converter control scheme based onimproved linear active disturbance rejection control(LADRC)was proposed. The linearized small sig...
更多
Number of views:5623 Amount of downloads:9380
-
WANG Yifeng,ZHANG Mingzhi,CHEN Bo,CHEN Mengying,CHEN Chen,XIE Wenqiang
Abstract: In order to provide a theoretical basis for the research of universal adapters in DC power distributionsystems,it is particularly important to fully understand the characteristics of DC household loads. A large number ofexperiments and tests were carried out on DC resistive home appliances among common DC ...
更多
Number of views:5574 Amount of downloads:8700
-
ZHOU Ye,CUI Shuangxi,FAN Xiaochao,WANG Weiqing,WU Binbing
Abstract: When the grid voltage is unbalanced,the negative sequence current will seriously affect the qualityof the output power of the grid-connected inverter. The detection speed of the grid information is one of the mainfactors of negative sequence current compensation. Therefore,a control strategy without phase-...
更多
Number of views:5574 Amount of downloads:8824
-
WANG Haijun,WANG Lei
Abstract: Aiming at the problem of active power dispatch and control in the grid-connected power system oflarge-scale wind power clusters(WPC)of distributed wind farms,a hierarchical model predictive control(HMPC)strategy based on dynamic power dispatch was proposed. Firstly,the dispatch framework was divided into f...
更多
Number of views:5572 Amount of downloads:9630
-
LIU Tao,CAI Xu,SUN Guoqi,WEI Xiaobin,CAO Yunfeng,ZHANG Lingyan
Abstract: As traditional condenser is replaced by static var generator(SVG),the dynamic reactive powercompensation can be provided by SVG. However,compared with traditional condenser,SVG lacks rotational inertia.Traditional research of SVG mainly focused on reactive power compensation and fault ride-through,and ther...
更多
Number of views:5566 Amount of downloads:12701
-
LI Chengyuan,ZHANG Chao,LI Zhe,LIU Bochang,GAO Jing,JIN Pengfei
Abstract: Due to the small capacity and weak regulation energy of island grid,it is very easy to cause systemcollapse. When the isolated grid collapses,it is necessary to establish the grid through its internal black start powersupply without relying on the external public grid. In recent years,with the rapid develo...
更多
Number of views:5531 Amount of downloads:9752
-
LI Yangyang,HU Jinlei,LAI Junju,WANG Wei,YANG Fan
Abstract: Aiming at the on-site live detection data of switchgear,a mean-shift clustering algorithm based onmulti-dimensional feature quantity was proposed to identify the abnormal partial discharge of switchgear. Theswitchgear partial discharge detection data which include dispersion,average distance percentage,con...
更多
Number of views:5519 Amount of downloads:9269
-
TANG Taonan,WANG Jian
Abstract: Aiming at the fault-tolerant operation problem of induction motor driving system with sensorfailures,a smooth fault-tolerant control strategy combining indirect field-oriented control(IFOC),direct torquecontrol(DTC)and V/f control was proposed. The indirect field-oriented controller and the direct torque c...
更多
Number of views:5505 Amount of downloads:11826
-
YAN Yuhao,ZHOU Buxiang,CHEN Shi,DONG Shen,LIU Zhifan,ZANG Tianlei
Abstract: At present,the focus of research on doubly fed induction generator(DFIG)high voltage ride through is a single high voltage fault.However,after DFIG low voltage ride through,due to the irrationality of the reactive power compensation strategy,a low/high voltage compound fault have be caused,which have a cer...
更多
Number of views:5486 Amount of downloads:12908
-
FAN Zhenning,SU Qiang,ZHANG Xinmin,ZHAO Changwei,XU Ke
Abstract: The control strategy of flexible multi-state switch(FMS)is a key technical challenge to ensure its highefficiency,reliability and flexibility. In order to solve the problems that the parameter design of proportional resonant (PR)controller is complicated and is greatly affected by grid frequency disturbanc...
更多
Number of views:5461 Amount of downloads:8884
-
GUO Leilei,ZHU Linqiang,CAO Lingzhi,LI Yanyan,WANG Pengshuai
Abstract: The accurate estimation of rotor angle is an important prerequisite for realizing speed sensorless highperformance vector control of permanent magnet synchronous wind generator. In the speed sensorless control ofpermanent magnet synchronous wind generator based on disturbance observer,the traditional angle...
更多
Number of views:5441 Amount of downloads:12785
-
GUO Dengke,MI Wentao,ZHUANG Feihu,XU Yiduan,FAN Ruini
Abstract: According to the requirements of quickly and reasonably formulating load transfer measures afterdistribution network failure at this stage,a reliability evaluation scheme for fault transfer based on K-fold verification was introduced. Square up various power supply modes,according to the energy balance equ...
更多
Number of views:5441 Amount of downloads:8252