-
DONG Yongle,ZHANG Jiang,ZHANG Lifang,ZHANG Qi
Abstract: In view of the increasing factors of power demand in our country,and the low efficiency of traditionalstatic model and adjustment mode of distribution network based on artificial experience,which can not meet thepractical needs of high-level applications such as refined line loss of distribution network. I...
更多
Number of views:5569 Amount of downloads:8747
-
ZHAO Jianyong,ZHANG Zhenxiao,DING Yuanjie,YU Ziwei,HAN Junyao, WANG Shenghong,NIAN Heng,LI Xuerong
Abstract: Aiming at the problems of small regulation range and slow speed of traditional voltage regulators such as compensation capacitors in distribution network line voltage compensation,a voltage compensation scheme of distribution network in sparse area was proposed,the voltage hierarchical coordinated control ...
更多
Number of views:5563 Amount of downloads:8675
-
LIN Xin,GAO Xiang,XIE Zhen,XU Kebao,ZHANG Xing
Abstract: With the increasing proportion of wind turbines,the characteristics of low inertia and weak dampingpower grid become more obvious,which brings new challenges to the smooth operation of power grid. Traditionalcurrent-controlled strategy is difficult to obtain accurate grid synchronization information in wea...
更多
Number of views:5558 Amount of downloads:13265
-
PAN Guangxu,GONG Chiyu,LI Xingyu,HU Jun,LI Yingjie,WANG Ruiqi
Abstract: As an essential part of power system design and operation scheduling,electric load forecasting istroubled by strong randomness and low accuracy. Moreover,the application of advanced forecasting algorithms isassociated with data management system,while the traditional data management system is very inconven...
更多
Number of views:5557 Amount of downloads:10122
-
PAN Ling,FENG Qian,ZHANG Peng,SHEN Bing,ZHOU Jian,CHEN Ran,ZHAO Jinshuai
Abstract: Due to the high cable ratio of city grid,the harmonic pollution is aggravated. For the buses with high harmonic voltage content,it is necessary to evaluate the harmonic emission level of the utility side and customer side. Most of the existing evaluation methods are based on two assumptions:1)the harmonic ...
更多
Number of views:5545 Amount of downloads:7824
-
GU Ming,XING Meng,GE Xianjun
Abstract: Aiming at the complex problem of weight factors tuning when the induction motor driving systemadopts the finite set model predictive control,an optimal finite set model predictive controller without weightdistribution for induction motor driving system was designed. In the new scheme,the form of sequential...
更多
Number of views:5541 Amount of downloads:8141
-
DUAN Huiqin,HUANG Zhiyong,DU Shuping,YAN Tianbi,WEI Yongheng,WEI Hongxing,CHENG Zhuo
Abstract: Bidirectional DC-DC converter is the key equipment to realize the power balance of DC microgrid,and the accurate distribution of load current is one of the main objectives of multi converter parallel control. Aimingat the current sharing problem of bidirectional DC-DC converter,a current sharing control ba...
更多
Number of views:5536 Amount of downloads:9693
-
NIU Qian,ZHANG Dong,WANG Junlong
Abstract: Aiming at the problems of uneven power distribution and poor stability of grid AC/DC microgrid,anew adaptive coordinated control strategy was proposed to improve the stability and power distribution accuracy ofAC/DC microgrid(MGs)system.First,for converters connectingAC microgrids and DC microgrids,a contr...
更多
Number of views:5533 Amount of downloads:8809
-
REN Hao,QIU Xiaoyan,ZHANG Zhirong,SUN Xu,ZHANG Mingke
Abstract: With the development of electric vehicle(EV),there are a large number of EV charging load in thepower grid. Because of its unique advantages,AC/DC microgrid is more convenient for the access of AC slowcharging pile and DC fast charging pile. However,large-scale EVs integration will bring impact to the powe...
更多
Number of views:5507 Amount of downloads:8216
-
LU Hai,ZHANG Xudong,DANG Junpeng,GUO Li,LIU Rui
Abstract: A 2-stage three-level power conversion system(PCS)was studied,in which the 3-level T-type 3-leg3-phase 4-wire(3LT23L3P4W)topology was adopted as AC/DC part while the 3-level Buck/Boost topology wasutilized as DC/DC interface. To address the neutral point potential(NPP)unbalance of the PCS,firstly,with thea...
更多
Number of views:5502 Amount of downloads:8581
-
FU Yu,LI Tie
Abstract: The microgrid is essentially an active distribution network,which is a combination of the distributed generation(DG)system and different loads at the distribution network voltage level. By analyzing factors such as safety and reliability,energy conservation and environmental protection in the microgrid,and...
更多
Number of views:5498 Amount of downloads:8831
-
CHEN Zhixiu,LIU Yang,ZHANG Hanshu,XIAYe,WANG Hao,LIU Xin
Abstract: In the period of high and new technology development,the application of SiC and other newsemiconductors promotes the development of PCB design toward integration and high efficiency. The new ideas were provided for PCB design optimization from two aspects of high frequency and high density. Among them,ther...
更多
Number of views:5482 Amount of downloads:9004
-
LU Yibing,LI Feng,ZHAO Wenbin,LU Wu,HUO Simin
Abstract: A power angle control method for DC system with doubly-fed induction generator based on air gapflux vector regulation was presented,which could reveal the relationship between the air gap EMF vector angle andthe stator output power,and could be used to directly control the stator output power. In the propos...
更多
Number of views:5475 Amount of downloads:8525
-
CHEN Lu,WANG Can,HU Hao,ZHOUYANG Junran,YANG Wentao,MA Xin
Abstract: With the increasing utilization rate of electric vehicles(EVs)in China,high permeability EVs makethe three-phase imbalance rate of urban distribution network increase day by day,which causes problems such asvoltage fluctuation and network loss increase,and the distribution network with high three-phase imb...
更多
Number of views:5466 Amount of downloads:10359
-
TANG Jiayuan,ZHAO Wenbin,LU Wu,GAO Yuan
Abstract: Under the electric power market environment,the key to achieve the joint operation of virtual powerplants lies in the profit distribution among the internal multi-subjects. To solve the impact of the final profitdistribution,which is caused by the uncertainty of the clean energy output of each main body in...
更多
Number of views:5457 Amount of downloads:8625