ZHANG Rui,XIAYan,HUANG Guiping,CHEN Renzhao,YANG Yili
Abstract:Aiming at the poor robustness and system vibration problem of asynchronous motors under thetraditional sliding mode control,a variability coefficient power exponent reaching law(VCPERL)was proposed todynamically change the control coefficients according to the position of the sliding mode surface,and the sl...
更多
Number of views:530 Amount of downloads:545
-
TANG Aiwu,CHEN Tianyou
Abstract:In order to effectively adjust and control the motion amplitude of the flexible manipulator and avoidlarge deviation between the actual motion track of the flexible manipulator and the target track,a flexiblemanipulator motion track control system based on the combination of distributed control system(DCS)a...
更多
Number of views:584 Amount of downloads:543
-
WANG Yanjie,LIN Chaobin,XU Guozhi,LI Qingyao,ZHANG Zhenye,HU Kun
Abstract:To adapt to the construction of a novel power system with new energy as the main body,it isnecessary to continuously improve the new energy consumption capacity of various voltage-level power grids.Through the research on the influencing factors and improvement methods of new energy consumption capacity ofd...
更多
Number of views:702 Amount of downloads:539
-
ZHOU Hao,DING Yu,WEI Xu,LI Xuesong,FAN Tianrong
Abstract:With the continuous promotion of the "double carbon" strategy,the reformation of China'selectricity market has entered a new stage,but the overall construction of the electricity market is still in theprimary stage,and there is an urgent need to develop a scientific and feasible regulatory prevention st...
更多
Number of views:656 Amount of downloads:538
-
LI Xinhai,FAN Dehe,MENG Chenxu,ZENG Lingcheng,YUANTuolai
Abstract: Due to various environmental factors,the relay platen status recognition needs manual inspection fora long time,and the current popular platen image recognition program requires a huge background computingarchitecture,which can not immediately obtain the verification information in the operation site,and s...
更多
Number of views:648 Amount of downloads:538
-
ZHANG Wei
Abstract:The multi-source monitoring data of switchgear contains rich equipment operating statusinformation,and analyzing it can achieve switchgear fault diagnosis. A fault diagnosis method for switchgear basedon SMOTE-SSA-CNN was proposed. Firstly,based on monitoring data such as switchgear voltage,current,andtempe...
更多
Number of views:340 Amount of downloads:536
-
HAN Song,YU Zhiqiang,WANG Mingyue,YU Hongze,JIA Pengfei
Abstract: Under the background of carbon emission reduction,fully controlled power device IGBT is widelyused in various of converters with its excellent performance,effective and reliable drive circuit is crucial to the safeoperation of IGBT,especially for high-power applications. Aiming at the requirement of flexib...
更多
Number of views:661 Amount of downloads:536
-
CUI Mengyu,YIN Qinglong,GUO Xudong,LÜ Tuo,HU Qifeng,LIU Zhengyan
Abstract:The VPX power standard is currently the most compatible military embedded computer standardinternationally,and its modules can stably power multiple different functional modules in the chassis. A VPXpower board based on VITA46 and VITA62 standards was designed. The design architecture,ideas,and functionsof ...
更多
Number of views:474 Amount of downloads:529
-
LIU Erhao,WANG Junqing,QIAO Lili
Abstract: Permanent magnet synchronous motor(PMSM)driving stable platform directly is often used inguided rockets to realize the decoupling control of stable platform. Due to the extended state observe(ESO)contained in the active disturbance rejection controller(ADRC),it can accurately estimate the speed of the rota...
更多
Number of views:654 Amount of downloads:521
-
XIANG Zhiping,MAYuhe,GAO Jian
Abstract:In order to reduce the loss of electric energy in the process of energy conversion and improve theenergy efficiency of aluminum air battery,an energy efficiency model based on the internal resistancecharacteristics of aluminum air battery was established,and the variations of operating conditions(operatingt...
更多
Number of views:428 Amount of downloads:518
-
YU Jialin,GUO Jinrui,TU Xiaodong,LIU Weiliang,ZHONG Weidong
Abstract:To address the issue of over/under voltage in the distribution network due to the scale access ofdistributed generators and flexible loads under the "double carbon" target,an active distribution networkscooperative voltage control strategy based on the active support of electric vehicles(EVs)aggregation wasp...
更多
Number of views:544 Amount of downloads:516
-
SU Yanlong,YANG Jun,WENG Yuyou,WANG Yuling,HU Yu,PAN Shitong
Abstract:In order to improve the stability and economy of photovoltaic-storage combined power station,acapacity optimization method of photovoltaic-storage system based on the whole life cycle was proposed. The basicmodel of the station was analyzed. The capacity optimization model of energy storage system was estab...
更多
Number of views:686 Amount of downloads:513
-
LIU Xianyi,SHI Xinghao,JIANG Yikang,PAN Xiumin,QU Le,HUANG Feng
Abstract:Aiming at the problem of low recognition accuracy of electricity stealing behavior,an electricitystealing behavior recognition model based on joint neural network was proposed. Firstly,the acquired userelectricity consumption data was processed,and the user electricity consumption data was two-dimensionally...
更多
Number of views:674 Amount of downloads:508
-
ZHANG Mingqi,YE Hong,LIANG Hao,ZHAO Bo,WANG Chao,WANG Kui
Abstract:Aiming at the problem that the circulating currents analysis of modular multilevel matrix converter(M3C)is not deep enough and the frequency component of circulating currents is not clear,the coupling process of submodule capacitor voltage fluctuation,bridge voltage fluctuation and circulating currents in M...
更多
Number of views:377 Amount of downloads:502
-
HUANG Licai,YANG Xu,ZHANG Jing,LUO Chuanxian,CHEN Jia,ZHANG Guozhi
Abstract:In view of the frequent occurrence of omissions and false alarms of partial discharge insulationdefects in on-site gas insulated switchgear(GIS),the partial discharge multi-source detection test platform was built by using true GIS to carry out the intermittent discharge test of metal contamination defect o...
更多
Number of views:554 Amount of downloads:499