-
ZHANG Kuangyi,LIU Haitao,MA Bingtai,ZHANG Chengyu
Abstract: There are many fault distributions along the actual distribution network lines,but the existingvoltage sag stochastic assessment methods only consider the uniform fault distribution. According to the differentfault distribution characteristics along the line,a stochastic assessment method of voltage sag wa...
更多
Number of views:2369 Amount of downloads:6322
-
ZHANG Jinbo,YIN Yuan,SHI Jian,LIN Shaoyuan,YAN Lei,HUANG Xiaoyu, LIN Yubin,YANG Dishan,CHENG Nuo
Abstract: In order to reduce the measurement error of transmission line crossing distance and reduce theoccurrence rate of transmission line accidents,a method of transmission line crossing distance measurement basedon grid information model was proposed. The platform of crossing distance measurement including data ...
更多
Number of views:4235 Amount of downloads:6316
-
WANG Pengcheng,PAN Ligang,WANG Yijie
Abstract: The emergence of wireless power transmission(WPT)technology overcomes the strict requirementsof traditional wire transmission process on transmission site conditions,maintenance convenience and security,which has a wide range of application scenarios. In the WPT technology,the misalignment tolerance charac...
更多
Number of views:2077 Amount of downloads:6314
-
FAN Peilin,HU Pengtao,XUE Jianli,LIU Zheng,HUANG Jinming
Abstract:Voltage source converter (VSC) is prone to low-frequency oscillations of 100~101Hz whenconnected to weak AC power grids. The mechanism of improving the control strategy of VSC on the traditionalinverter side to suppress low-frequency oscillations(LFO)in the AC power grid is to transfer the oscillations from...
更多
Number of views:1532 Amount of downloads:6310
-
ZHOU Ye,CUI Shuangxi,FAN Xiaochao,WANG Weiqing,WU Binbing
Abstract: When the grid voltage is unbalanced,the negative sequence current will seriously affect the qualityof the output power of the grid-connected inverter. The detection speed of the grid information is one of the mainfactors of negative sequence current compensation. Therefore,a control strategy without phase-...
更多
Number of views:4930 Amount of downloads:6310
-
LI Haoyuan,CHEN Guowei,LI Guanjun,WEI Lingfeng,LIN Da,WANG Xiangjin
Abstract:With the emergence of a large number of distributed power generations,various unbalanced andnonlinear loads are connected to the power grid,resulting in the distortion of the grid current,which brings adverse effects to both the power grid and electrical equipment. A multifunctional energy storage converter...
更多
Number of views:1731 Amount of downloads:6309
-
LIU Xinglong,XIE Yihan,YANG Ziyang,ZHANG Zhilong,YI Hao,ZHUO Fang
Abstract:Active power filters(APF)are widely used for dynamic compensation of power system harmonic.However,under weak grid conditions,the interaction between APF,nonlinear loads and grid impedance can easily lead to the stability issue of harmonic oscillation around the compensation frequency,resulting in the fault...
更多
Number of views:2697 Amount of downloads:6305
-
WANG Peng,LI Zhongzhao,GONG Zhaowei,ZHANG Ningchao
Abstract: In order to solve the problem of coupling mechanism offset in wireless power transfer system,theS-S and LCC-LCC dual topological wireless power transfer system based on parameter optimization was proposed.Firstly,the output characteristics of S-S and LCC-LCC topological energy transmission channels were an...
更多
Number of views:4034 Amount of downloads:6298
-
ZENG Jiang,XIONG Taojun,XIE Baoping,ZHAO Benqiang,MA Haijie
Abstract: Aiming at the deficiency that the traditional active power filter(APF)can only control the localharmonic source,a harmonic active defense system(HADS)based on virtual harmonic resistance was proposed.The principle of harnessing harmonics in distribution network by HADS was analyzed,the HADS simulationmodel...
更多
Number of views:2337 Amount of downloads:6297
-
JIAO Xiaofeng,WEI Chao,HU Hongbin,FAN Zeguo,ZHANG Lihui
Abstract: With the acceleration of my country' s power spot market construction process,in order to solve theproblem of heat-electricity mismatch in the northern region,two different day-ahead scheduling strategies of aflexible co-generation plant based on the participation of cogeneration units in the day-ahead...
更多
Number of views:2661 Amount of downloads:6295
-
WU Ning,CAI Jie,LIANG Gonghao
Abstract: As an important part of smart grid monitoring system,the security of power wide area measurementsystem is very important. Therefore,in order to ensure the integrity and confidentiality of communication data inpower wide area measurement system and the communication security between terminal devices in the ...
更多
Number of views:2113 Amount of downloads:6287
-
DAI Yanwen,YU Aiqing
Abstract: In order to improve the reliability of microgrid operation and renewable energy power absorbability,a capacity optimization allocation method of energy storage system based on improved nondominated sortinggenetic algorithm Ⅲ( NSGA-Ⅲ )was proposed. Firstly ,a two-layer optimization model of energy storageco...
更多
Number of views:3885 Amount of downloads:6287
-
ZHOU Wen,YANG Shaobo
Abstract: In the DC microgrid,bus voltage stability is the key to maintain the normal operation of the system.Load switching and distributed micro-source power fluctuations will affect the stability of the DC bus voltage. Tosolve the above problem,a compensation control strategy based on the residual generator was p...
更多
Number of views:3651 Amount of downloads:6285
-
HE Hengjing,ZHOU Shangli,ZHANG Bensong,XIE Wenwang,LIAN Xinkai,XU Haotian
Abstract: In order to apply the non-instrusive load montiring technology into the new generation of smartmeter,a kind of method based on the BP neural networks enhancement algorithm of clustering for loadidentification was presented. In this method,each feature was relatived to the corresponding cluster based on the...
更多
Number of views:3520 Amount of downloads:6283
-
YANG Shude1,ZENG Zikang,ZHANG Xinwen,GAO Xiongying,CAI Changhong,ZHOU Xin
Abstract: For the technical requirements of on-load voltage regulation based on power electronic switches,athyristor-based on-load voltage regulation unit topology was given based on the analysis of the possible conduction state of each switch in the steady state and the switching law of different states. Considerin...
更多
Number of views:4220 Amount of downloads:6282