-
YUAN Shaowei,LI Yuxiang,JIANG Jie,ZHANG Bei,ZHU Qing
Abstract:In order to solve the problems of intermittent and fluctuating distributed energy,took three majorphysical entities in the demand response project,namely system operator,load aggregator and load end user,as the research object,the transactions between supply and demand within the power system composed by the...
更多
Number of views:2661 Amount of downloads:9323
-
JIAO Jinghai,LI Jie
Abstract: To solve the problem of low identification accuracy of partial discharge(PD)for electric multipleunits ethylene propylene rubber(EPR)cable terminal defects,an on-board cable terminal defect identificationmethod based on improved residual network was proposed. Firstly,cable terminals with four typical insul...
更多
Number of views:2661 Amount of downloads:10012
-
PENG Yanlai,FAN Yong,YANG Xiaofeng,YANG Hongyu,WANG Zhixin
Abstract: Aiming at the problems that the amount of data in wind farm SCADA data is huge and it is difficultto classify the fast fault of wind turbine generator,a dynamic threshold AdaBoost algorithm(DTAdaBoost)wasproposed. Based on AdaBoost algorithm,the dynamic threshold was introduced to screen the sample set dat...
更多
Number of views:2659 Amount of downloads:7377
-
DONG Yue,HE Yingfei,DU Lulu,TANG Mingjie,JIN Guangchao,ZHAO Jing
Abstract:Modular multi-level matrix converter(M3C)is a kind of new topology which can convert onespecified electric frequency to another directly,it is applicable to high voltage and large capacity scene. In thefractional transmission system,the complete flow was introduced to achieve power frequency grid fault ride...
更多
Number of views:2658 Amount of downloads:10862
-
YU Shengcan,YU Tao,FENG Miaoyong
Abstract:Accurately and quickly identifying the fault types of traction transformers is a key technology forintelligent operation and maintenance. Aiming at the problems of single model deviation in the current traditionalalgorithm and the constraints between the iteration rate of complex models and the deployment o...
更多
Number of views:2652 Amount of downloads:8800
-
XU Shizhou,CHANG Jinhai,FAN Jingsheng,JIA Xinxin
Abstract:A method for establishing edge triggered pulse control switch state time was proposed to address thedivergence of floating capacitor voltage and DC capacitor midpoint voltage in a 5-level active neutral point clamped(ANPC-5L)inverter using the space vector pulse width(SVPWM)algorithm in the g-h coordinate s...
更多
Number of views:2647 Amount of downloads:8752
-
GUO Jiahao,YANG Xiong,FANG Xin,GUAN Jiamin
Abstract: The secondary voltage signal output by electronic capacitive voltage transformer in the primary andsecondary fusion equipment is very weak,which is easy to be interfered by high-order harmonics,resulting inunstable signal transmission. In order to solve these problems,a high-order and high-precision filter...
更多
Number of views:2647 Amount of downloads:9018
-
ZHOU Jinwei,DING Dawei,JIANG Xuexiang,REN Zhaoting,LI Xizhi
Abstract:Maximum torque per ampere(MTPA)control can effectively improve system efficiency throughreducing copper loss,which is suitable for air conditioning permanent magnet compressor system. However,due to the inverter non-ideal characteristics,the tracking accuracy of the optimal current vector angle decreases. T...
更多
Number of views:2646 Amount of downloads:8129
-
WANG Huahan,ZHAO Shiwei
Abstract:A dual active bridge(DAB)DC-DC converter voltage control strategy based on double-integralsliding mode control was proposed,which can obtain good control effect under the condition that the modelaccuracy requirements are low and the controller design process is simple. Firstly,the reduced-order model of the...
更多
Number of views:2645 Amount of downloads:9101
-
QI Zhenbiao,BAO Yuying,FAN Shen,PAN Min,HU Pengfei,WU Hongbin
Abstract:In the multi-source measurement system of distribution network,the sampling frequency and timestamp of multi-source measurement equipment are not synchronized,as well as the bad data in the system,whichwill lead to the bias among the measurement data,thus affecting the accuracy of state estimation. To this ...
更多
Number of views:2642 Amount of downloads:13249
-
SONG Pengfei,WANG Maxiang,YANG Guixing,LI Jichen,KANG Pengpeng,WEN Shenghan
Abstract:To enhance the economic and operational flexibility of accompanying energy storage facilities innew energy power stations,as well as to improve the stability of supplying electricity directly to large users and thegrid-friendliness of large-scale new energy power stations,a two-stage robust configuration an...
更多
Number of views:2642 Amount of downloads:10614
-
DU Jifei,WANG Yang,WANG Li,LIU Haoruo,MU Yunfei,SUN Qiang
Abstract:The primary side feedback can stabilize the output voltage,and improve the service life of theequipment without using the secondary winding detection error signal. The topology of active filter and theimproved method of primary side feedback were adopted. The performance of active EMI filter topologies wasa...
更多
Number of views:2641 Amount of downloads:9671
-
CAI Weiliang,CHENG Haifeng,PAN Zhixuan,CHENG Jin,DAI Mingli
Abstract: The grid connection of doubly-fed induction generator(DFIG)leads to the reduction of systemequivalent inertia and primary frequency regulation capacity. With the increase of DFIG grid connection scale,theproblem of system frequency regulation becomes more and more serious. In view of this problem,frequency...
更多
Number of views:2637 Amount of downloads:7672
-
LI Ning,WANG Ruyue,ZHU Longhui
Abstract:In order to analyze the power quality problem of actual power network under the influence ofuncertain interference factors,a power quality detection and recognition method combining empirical wavelettransform(EWT)and improved S-transform was proposed. On the one hand,the frequency,amplitude and timeparamete...
更多
Number of views:2636 Amount of downloads:8520
-
YANG Zhenyu,WANG Wei,XU Wenzheng,ZUO Zhiling,CHEN Changqing
Abstract:The telecommunication power supply applied in 5G base stations can save energy consumption byreducing the output voltage when the equipment works in standby state. Nevertheless,frequent and rapid outputvoltage regulating of the converters is challenging. To solve this problem,the concept of partial power co...
更多
Number of views:2635 Amount of downloads:7996