Abstract:The primary side feedback can stabilize the output voltage,and improve the service life of the
equipment without using the secondary winding detection error signal. The topology of active filter and the
improved method of primary side feedback were adopted. The performance of active EMI filter topologies was
analyzed from insertion loss and equivalent circuit,the active filter with voltage sampling and current compensation
was adopted. Through describing the mechanism of primary-side feedback of sampling knee point voltage,the
small signal modeling of the converter in discontinuous current mode(DCM) was carried out,and the
compensation network was designed to ensure the stability. The simulation and experimental results show that the
active EMI filter can effectively replace the traditional filtering method,and the original side feedback method can
detect and correct the output voltage fluctuation to ensure the voltage stability.
Key words:power converter;small signal model;primary side feedback;active EMI filter