LIU Dongchao,XIONG Muwen,GAO Sen,ZHAO Senlin,ZHU Herong,LI Haitao
Abstract: Different types of partial discharge (PD) in gas insulated switchgear (GIS) cause different damage toGIS insulation. Correctly identifying the type of partial discharge is very important to evaluate the insulation statusof GIS. In order to simplify the process of feature extraction and improve the recognit...
更多
Number of views:5944 Amount of downloads:9775
-
SUN Lihua,ZHANG Lin,SUN Huiqin,GUO Yingjun,LI Zheng,GUO Tianliang
Abstract: The switched reluctance motor control system for electric vehicles includes motor drive and batterycharging circuit,which reduces system integration and power density. Based on the asymmetric half-bridge powerconverter of switched reluctance motor,an integrated power converter for electric vehicle was desi...
更多
Number of views:5682 Amount of downloads:8634
-
HU Bo,YANG Chao,TIAN Xiaolei,LI Yunlu,YANG Junyou,CUI Jia
Abstract: When the internal parameters and topology of grid-connected power converter is unknown in somepractical applications,the existing frequency scanning based impedance modeling method can only maintain thedynamic equivalence at one operating point. To ensure the effectiveness of dynamic model in a wide operat...
更多
Number of views:6117 Amount of downloads:8708
-
GAO Fengliang,HUANG Xiongfeng,FAN Hongxing,ZHANG Xuankun
Abstract: The failure rate of IGBT devices caused by excessively high temperature is as high as 55%.Improving the heat dissipation efficiency of the heat sink is the basis for ensuring the safe and reliable operation ofIGBT devices. Through theoretical analysis of IGBT module water cooling and heat dissipation,a tem...
更多
Number of views:5794 Amount of downloads:10717
-
ZHOU Liying,XIA Changhao
Abstract: Three-phase bridge converters(TPBC)are widely used in low-voltage power distribution networksto compensate the negative-sequence current and the reactive current. Because of the relatively high costs,improving the compensation effect of limited capacity equipment has high economic value and research signif...
更多
Number of views:5741 Amount of downloads:9008
-
ZHANG Lantao,XIONG Jun,NIU Xiaonan,HUANG Xiaoyu
Abstract: Aiming at the reliability problem of high-power IGBT modules under short circuit extreme operatingconditions,the power terminals imbalanced current of IGBT modules and the resulting dynamic junctiontemperature change were comprehensively analyzed. Firstly,the current sharing characteristics of parallel ter...
更多
Number of views:5681 Amount of downloads:9613
-
ZHAO Jianyong,LI Han,WU Min,MA Runsheng,ZHAO Wenqiang,YU Ziwei
Abstract: Firstly,the significance of impedance modeling for new energy power generation equipment wasanalyzed,and the existing impedance modeling methods were explained. Aiming at the problems of low flexiblematching degree,single disturbance signal,fixed disturbance frequency and the inability of real-time measure...
更多
Number of views:5640 Amount of downloads:9966
-
NIU Qian,ZHANG Dong,WANG Junlong
Abstract: Aiming at the problems of uneven power distribution and poor stability of grid AC/DC microgrid,anew adaptive coordinated control strategy was proposed to improve the stability and power distribution accuracy ofAC/DC microgrid(MGs)system.First,for converters connectingAC microgrids and DC microgrids,a contr...
更多
Number of views:5536 Amount of downloads:8816
-
ZHOU Jiabin,CHEN Yufe,GU Zhaoliang,YONG Jun,ZHAO Wenbin,JIANG Pengliang
Abstract: The influence of magnetic bias current on the excitation characteristics of near-field transformers inthe DC grounding electrode from bipolar to unipolar earth mode was discussed. Based on the principle of field-circuit coupling,the DC magnetic bias co-simulation model of transformer was established and an...
更多
Number of views:5763 Amount of downloads:9618
-
ZHANG Yang,GAO Tian,LIN Weixing
Abstract: Photovoltaic inverter,charging pile,energy storage converter,wind power converter and othercommon power electronic equipment are three-phase high frequency AC/DC/DC converter,which is widely used inindustrial and civil fields. Due to the fast switching capability of three-phase high frequency converter,its...
更多
Number of views:5924 Amount of downloads:10310
-
MA Tianhui,MAWeiwei,GU Huaiguang,LIU Dong
Abstract: The modular multilevel converter(MMC)based high voltage direct current(HVDC)system(MMCHVDC)is an ideal solution for large-scale grid-connected and clustered offshore wind farms. But the interaction between the doubly fed induction generator(DFIG)and the MMC-HVDC system has a risk of subsynchronous oscillat...
更多
Number of views:6151 Amount of downloads:9351
-
LU Hai,ZHANG Xudong,DANG Junpeng,GUO Li,LIU Rui
Abstract: A 2-stage three-level power conversion system(PCS)was studied,in which the 3-level T-type 3-leg3-phase 4-wire(3LT23L3P4W)topology was adopted as AC/DC part while the 3-level Buck/Boost topology wasutilized as DC/DC interface. To address the neutral point potential(NPP)unbalance of the PCS,firstly,with thea...
更多
Number of views:5503 Amount of downloads:8593
-
FU Xuhui,FANG Chun'en,XUE Tao,HUANG Leichao,CHEN Junping
Abstract: In order to ensure that the thyristor valve body can be accurately conducted during the solid state switch switching,a solid state switch trigger control unit was designed. Firstly,the structure and working principle of the solid state switch and the structure and function of the trigger control unit were ...
更多
Number of views:6124 Amount of downloads:9008
-
YIN Aihui,REN Ang,WU Xiaowen,HOU Jianfeng,FAN Yulin
Abstract: When fast voltage control is used in a power factor corrector(PFC),ripples on the DC side can cause grid current harmonics. To solve this problem,a novel DC voltage nonlinear PI control strategy was proposed,which could reduce the harmonic content of fast voltage closed-loop in power factor corrector. Base...
更多
Number of views:5679 Amount of downloads:7079
-
PAN Ling,FENG Qian,ZHANG Peng,SHEN Bing,ZHOU Jian,CHEN Ran,ZHAO Jinshuai
Abstract: Due to the high cable ratio of city grid,the harmonic pollution is aggravated. For the buses with high harmonic voltage content,it is necessary to evaluate the harmonic emission level of the utility side and customer side. Most of the existing evaluation methods are based on two assumptions:1)the harmonic ...
更多
Number of views:5547 Amount of downloads:7834