YANG Xiaochu,WANG Guanwen,LUO Guogan,XU Shipeng,ZHANG Dingwang
Abstract: The composition of the double-fed induction generator(DFIG)is complex,and its operation andmaintenance are difficult. Due to the relatively complex electromagnetic transient characteristics of the fault,theextraction quality directly affects the reliability of the fault detection results of the DFIG. Aimin...
更多
Number of views:934 Amount of downloads:767
-
LIAO Zhiwei,ZHUANG Jing,WANG Bowen,ZHENG Guangyu,XIE Xunkai
Abstract: Aiming at the problems that high voltage direct current(HVDC)transmission line protection andfault location are vulnerable to lightning interference,and the traditional lightning interference identificationmethods of transmission line based on time-domain and frequency-domain features exist the problems of...
更多
Number of views:783 Amount of downloads:955
-
XIAO Quan,ZHOU Xiaoshan,WANG Ruiqing,LIU Yuqi,ZHAO Xianyuan
Abstract: The excitation control module of synchronous generator is the key equipment for power productionand safe operation,and the localization rate of its key materials is low. Based on the control performance of thesynchronous generator excitation control module,starting from the research of chip independent con...
更多
Number of views:1237 Amount of downloads:904
-
GONG Yanchao,YANG Haiyun,MIAO Junjie,GAO Zhi
Abstract: Parallel capacitor banks can effectively improve the efficiency and quality of power transmission inthe application process of power distribution network. However,due to some unreasonable factors in the switchingmode of power capacitors,it will also generate overvoltage,thus affecting the power grid. stabi...
更多
Number of views:1210 Amount of downloads:879
-
TIAN Kai,YU Zhibin,YUAN Yuan,CHU ZiLin,CHEN Yujie,SUN Chuanjie
Abstract: A test method was proposed that can evaluate the ultimate power output capability of large capacityIGCT three-level converter. Based on synchronous symmetrical PWM modulation and temperature estimationmodel,the power experiment of IGCT three-level converter was carried out,which can test the equipment capa...
更多
Number of views:1167 Amount of downloads:889
-
YANG Tianxiang,CHENG Zhijiang,YANG Handi,TIAN Feng
Abstract: Aiming at the demand of intelligent coal mine and exit problem of underground coal mine powernetwork,an energy storage hybrid distribution transformer based on modular multilevel converter(MMC-HDT)was proposed. Firstly,the proposed energy storage MMC-HDT was modeled and four operation modes were givenconsi...
更多
Number of views:1058 Amount of downloads:1152
-
JIA Dexiang,ZHONG Cheng,LIU Zhanjie,ZHENG Houqing,GUO Yang
Abstract: Photovoltaic(PV)generation usually operates in maximum power point tracking(MPPT)mode,which cannot provide inertia and frequency support for the power system. Virtual synchronous generator(VSG)control is an attractive control method that can provide the similar behavior of synchronous generator(SG).However...
更多
Number of views:1159 Amount of downloads:1039
-
KANG Jiale,ZHOU Xuntian,ZHANG Zhigang,CEN Yinwei
Abstract: In order to improve the utilization rate of clean energy and promote the stable and low-carbonoperation of the microgrid,a low-carbon optimal dispatching model based on load side flexible resources wasestablished. According to the flexibility resource analysis,the flexibility resource modeling of load side...
更多
Number of views:1171 Amount of downloads:1004
-
WANG Yajing,ZHANG Shuai,JIANG Han,SONG Hongliang
Abstract: In order to improve the carrying capacity and resilience margin of the distribution network systemcontaining microgrid,a topological resilience optimization model of the distribution network system containingmicrogrid was established to achieve the resilience optimization objective of the distribution netw...
更多
Number of views:1091 Amount of downloads:896
-
JIA Junqing,ZHANG Yifan,PAN Dazhi,LIANG Shuai,YANG Yang
Abstract: Under the background of the increasingly prominent voltage sag problem in modern power grids,itis of great engineering significance to accurately identify the users' profile of demand of voltage sag control forguiding users' precise investment decisions for voltage sag control and helping power gri...
更多
Number of views:983 Amount of downloads:847
-
PAN Lingling,ZHUANG Weijin,ZHAO Qi,TIAN Jiang
Abstract: In the background of the new power system,the importance of demand-side dispatchable resourcesof the grid for system stability is increasing. As an important dispatchable load resource,an accurate assessment ofelectric vehicle(EV)dispatchable potential can effectively improve the safety and stability of th...
更多
Number of views:921 Amount of downloads:979
-
HU Dong,HU Jingtao,ZHANG Wentao,LÜ Feichun,WU Xu
Abstract: Photovoltaic(PV)power generation is an important power generation method to achieve the goal ofcarbon neutrality. During the grid connection of PV power generation system,due to the characteristics of inverterand the influence of nonlinear load,high-order harmonics are generated,the power quality of the po...
更多
Number of views:1061 Amount of downloads:929
-
HUANG Feng,CUI Zhimei,HUANG Zhidu,JIANG Shengchao,FENG Bo
Abstract: In order to evaluate the safety status of transmission lines scientifically and objectively,a safetyanalysis model of transmission lines based on support vector machine-back propagation(SVM-BP)hybrid networkwas proposed. Firstly,the weather data,transmission line standard documents and defect data were pro...
更多
Number of views:981 Amount of downloads:833
-
WU Ning,CAI Jie,LIANG Gonghao
Abstract: As an important part of smart grid monitoring system,the security of power wide area measurementsystem is very important. Therefore,in order to ensure the integrity and confidentiality of communication data inpower wide area measurement system and the communication security between terminal devices in the ...
更多
Number of views:1235 Amount of downloads:820
-
PENGTao
Abstract: The local leakage signal of high-voltage insulation equipment is weak and its characteristics are notobvious,which can only explain whether there is discharge. There is a phenomenon of missing judgment andmisjudgment in the actual positioning process,which is difficult to accurately locate the high-voltage...
更多
Number of views:1125 Amount of downloads:741