LIU Xinglong,XIE Yihan,YANG Ziyang,ZHANG Zhilong,YI Hao,ZHUO Fang
Abstract:Active power filters(APF)are widely used for dynamic compensation of power system harmonic.However,under weak grid conditions,the interaction between APF,nonlinear loads and grid impedance can easily lead to the stability issue of harmonic oscillation around the compensation frequency,resulting in the fault...
更多
Number of views:2708 Amount of downloads:6332
-
LI Wei,LUO Cheng,YANG Kai,WANG Xuming,QIU Lingfeng,HUANG Yuhao
Abstract:When the permanent magnet assisted synchronous reluctance motor(PMaSynRM)runs at highspeed with flux-weakening control,the DC bus voltage utilization is not high,and the efficiency and torque output capacity of the motor are low. Therefore,a flux-weakening control strategy of permanent magnet assistedsynchr...
更多
Number of views:2667 Amount of downloads:7637
-
WANG Xuming,LUO Cheng,XIONG Zhi,YANG Kai,XU Zhijie,LI Yinbin
Abstract:In response to the complex working environment of pumped storage energy units,wheredisturbances such as temperature variations are prominent,and considering the insufficient control precision oftraditional vector control for brushless doubly-fed machine(BDFM),a study was conducted on a control strategybased...
更多
Number of views:2922 Amount of downloads:7422
-
ZHOU Jie,ZHAO Shiwei,WU Yihao,YANG Xiangyu
Abstract:In order to optimize the current stress of dual active bridge(DAB)converter,an improved dualphase shift(IDPS)modulation was proposed based on the traditional dual phase shift(DPS)modulation. Firstly,the working principle of IDPS modulation was introduced,its steady-state working characteristics were analyze...
更多
Number of views:2336 Amount of downloads:7215
-
FAN Enze,LI Yaohua,GE Qiongxuan,ZHAO Lu
Abstract:Under digital control,the inner current loop of the LC-type inverter is affected by the control delay,which leads to the weakening of its active damping effect. Increasing the sampling control frequency can effectivelyreduce the negative influence of digital control delay. Furthermore,in order to suppress t...
更多
Number of views:2172 Amount of downloads:5939
-
ZHANG Jun,GONG Min,ZHOU Yi,XIE June,CAO Lei,LIU Yingying
Abstract:In traditional current protection,the effective value of current is compared with the setting value toidentify the fault which is the typical protection scheme for the transmission lines of the power distribution systems.The current is calculated by the fast Fourier transform algorithm. As the calculation o...
更多
Number of views:2170 Amount of downloads:5068
-
CHEN Sisi,LI Zhigang,ZHENG Jiehui
Abstract:The energy flow analysis method with both high precision and high computational efficiency is abasic tool to simulate the operation and analyze the interaction between the thermal and electric coupling systems.The traditional iterative numerical method is slow in computation,poor in computability for large-...
更多
Number of views:1851 Amount of downloads:6954
-
XING Gang,LIU Huihong,WANG Bozhao,SONG Wenyang,LIU Longfei,XU Xiandong
Abstract:To address the need of carbon emission peak and carbon neutrality target on local energy systems,an optimal expansion planning method of heat pump was proposed for regional energy stations considering thebenefits from ancillary services. The method was used to support the integration of new technologies suc...
更多
Number of views:1917 Amount of downloads:6629
-
JIANG Xuejiao,ZHANG Changqing,QIN Gang,ZHONG Lei,ZHOU Chaojun,CHEN Yupei
Abstract:In order to balance the output difference between renewable energy and load in the activedistribution network and reduce the budget cost and user purchase cost,an optimal dispatching method ofdistributed generation units in the active distribution network based on power demand side response was proposed.On ...
更多
Number of views:1778 Amount of downloads:4882
-
XU Deshu,LIU Yanfang,ZHAO Hao,MA Zhiqiang
Abstract:The integrated energy system contains adjustable resources and flexible operating modes,which to acertain extent play a supporting role in the power grid and assist in optimizing its operation. Based on this,anoptimal operation model of integrated energy system considering support capacity to power grid was...
更多
Number of views:1492 Amount of downloads:5402
-
TIAN Zhidan,YU Xiang,WAN Haibo
Abstract:In order to solve the problems of high subjective misjudgment rate and low efficiency in manualhand touch and auscultation methods for acoustic quality detection of micro motors,while taking into account theaccuracy of detection results and the fast construction of detection models,a small sample machine le...
更多
Number of views:1559 Amount of downloads:4628
-
YU Hui,ZHOU Shigui ,MA Feihong,ZHANG Kecheng
Abstract:Permanent magnet synchronous machines(PMSM)has serious chattering problem when traditionalsliding mode observer(SMO)is applied to low-speed operation with fixed sliding mode gain. To solve thisproblem,a full-order sliding mode observer(FSMO)with fuzzy adaptive adjustment of sliding mode gain wasproposed,whi...
更多
Number of views:2670 Amount of downloads:5255
-
MAYoujie,HE Xiaoyu,ZHOU Xuesong,ZHANG Chao
Abstract :To solve the chaos problem of inverter in new energy generation system,a regulation scheme ofH-bridge inverter based on active disturbance rejection contro(l ADRC)was proposed. Aiming at the phenomenon of poor steady-state and dynamic characteristics of inverters in chaotic state,a discrete model of the in...
更多
Number of views:2565 Amount of downloads:6657
-
SONG Weiqiong,GUO Shuai,HAN Liu,XU Chaoqun,SONG Wei,LÜ Fengming
Abstract:In order to monitor current distribution state of parallel silicon carbide(SiC)devices in photovoltaicinverter,a contactless monitoring solution based on anisotropic magnetoresistive sensor was proposed. Accordingto practical position of SiC devices on PCB board,multiphysics simulation tool COMSOL was emplo...
更多
Number of views:2277 Amount of downloads:6089
-
FANG Lei,CHU Chengbo,ZHU Xiaojing,HE Yinghong,YANG Huimin
Abstract:In order to address the issue of large output voltage variation from self-powered current transformerin smart measurement switch,ultra wide input voltage range post-stage DC-DC module is required to generatestable system voltage rails. A ultra wide input DC-DC module based on constant on-time control and as...
更多
Number of views:2717 Amount of downloads:6258