Browse ranking
Current location:Home >Browse ranking
-
SUN Lunan,ZHOU Yong,LIU Xiaodong,LIU Yawei,WANG Haoyu
Abstract:Combined with the current software features and the requirements for function expansion of thecurrent test equipment engineering project,a set of test data analysis system was designed. The system includes the functions of remote test data monitoring,historical data playback,test data analysis,data predicti...
更多
Number of views:500 Amount of downloads:223
-
LI Nengjun,YANG Haicheng,XU Xianke,LI Shushan,GAO Yuling
Abstract:The state of the DC system of substation is directly related to the normal operation of the substation.A new method for ground fault detection in substation DC systems,which is a combination of double-tree complexwavelet transform and singular value decomposition,was proposed to achieve fast and accurate lo...
更多
Number of views:494 Amount of downloads:406
-
JIN Dan,ZHI Jing,XIN Shijin,YANG Jian,HUANG Yafei,XU Qing
Abstract:Voltage source converter(VSC)connected to weak AC power grid has the risk of small disturbanceinstability. Under the traditional control strategy,VSC has to reduce output power to maintain stable operation. Inorder to improve the stability of the weak grid connected VSC system,first established a universal ...
更多
Number of views:493 Amount of downloads:526
-
YUAN Yisheng,HUANG Yikun,CAO Hui,HUANG Zhimin
Abstract:A bidirectional isolated resonant converter with variable mode and wide voltage range wasproposed. The proposed converter has the advantages of BOOST circuit and flyback current feed topology. Byreusing the pre-storage and flyback energy feedback of the resonant inductor,it can improve the gain from thebatt...
更多
Number of views:490 Amount of downloads:483
-
YU Shengcan,YU Tao,FENG Miaoyong
Abstract:Accurately and quickly identifying the fault types of traction transformers is a key technology forintelligent operation and maintenance. Aiming at the problems of single model deviation in the current traditionalalgorithm and the constraints between the iteration rate of complex models and the deployment o...
更多
Number of views:487 Amount of downloads:221
-
TANG Aiwu,CHEN Tianyou
Abstract:In order to effectively adjust and control the motion amplitude of the flexible manipulator and avoidlarge deviation between the actual motion track of the flexible manipulator and the target track,a flexiblemanipulator motion track control system based on the combination of distributed control system(DCS)a...
更多
Number of views:480 Amount of downloads:363
-
WANG Chunhui,QU Xiaowei,WANG Mingyue,HAN Song,LI Teng
Abstract:In order to improve the debugging and fault monitoring and analysis capabilities of inverterproducts,the design scheme of network version process data acquisition and analysis software was proposed.Thecomposition and implementation of the software system were discussed,and the technical means such as multit...
更多
Number of views:479 Amount of downloads:391
-
LI Shengnan,HE Tingyi,HE Xin,HE Peng,ZHANG Yongchang,ZHANG Shengan
Abstract:During the joint operation of permanent magnet direct drive wind power generation systems,thechanges in motor side parameters may cause problems such as reduce control accuracy and stability on the machineside,which in turn affects the DC bus voltage of the converter,leading to power fluctuations on the gri...
更多
Number of views:477 Amount of downloads:495
-
HU Qingjun,CAO Xinhui,FENG Yu,ZHU Lipeng,ZHAO Wenjing,WEI Yushan
Abstract: The process automation control system L2 of an aluminum zinc plating production line wasexplored. In response to potential production faults on the production line,a process data control module of theprocess automation control system was provided. Through the analysis of process data,the fault location of ...
更多
Number of views:477 Amount of downloads:437
-
CHEN Ling
Abstract: With the large increase of load users,the load side adjustable resources gradually increase,and theload side demand response(DR)resources are used to participate in microgrid scheduling to improve the level ofnew energy consumption. In order to give full play to the scheduling potential of DR resources and...
更多
Number of views:475 Amount of downloads:383
-
XIA Tao,LIU Liang,ZHANG Yangfei,LIU Haitao,MENG Gaojun
Abstract:Aiming at the problem of large output voltage fluctuation and long recovery time of three-phasepulse-width modulation(PWM)rectifiers when the load changes,an improved single-neuron gradient learningcontrol strategy was proposed. Due to the poor adaptability of the traditional PI controller parameters when t...
更多
Number of views:474 Amount of downloads:363
-
CHEN Dongdong,ZHANG Shengqi,XIAO Long
Abstract:Due to the wide control bandwidth of the shunt active power filter(SAPF),the resonance problemof the LCL output filter has become a key problem of the SAPF. To solve the resonance problem of the LCL filter,anovel damping method based on active damping circuit was proposed to achieve the damping effect witho...
更多
Number of views:469 Amount of downloads:311
-
YANG Zhenyu,WANG Wei,XU Wenzheng,ZUO Zhiling,CHEN Changqing
Abstract:The telecommunication power supply applied in 5G base stations can save energy consumption byreducing the output voltage when the equipment works in standby state. Nevertheless,frequent and rapid outputvoltage regulating of the converters is challenging. To solve this problem,the concept of partial power co...
更多
Number of views:468 Amount of downloads:353
-
ZHOU Liang
Abstract:Under the change of island operation conditions,the microgrid will cause that the digital twin(DT)model cannot accurately match the source domain model when migrating,which will lead to low migrationefficiency and other problems. For this reason,an adaptive migration method of digital twins model under thes...
更多
Number of views:467 Amount of downloads:359
-
LI Yunwang,CHEN Junde,ZHANG Daping,SANG Yun,HAN Xiaolei
Abstract:An adaptive active arc suppression method based on S-transform correlation degree for distributionnetwork unidirectional grounding was proposed to effectively eliminate single-phase grounding fault arc indistribution network and improve power system stability. The time series data of zero-sequence current o...
更多
Number of views:467 Amount of downloads:218